determine seismic forces for non-building structures Flashcards
non building structures similar to buildings
determination of seismic factors - R, Ω & Cd
ASCE 7 - table 15.4-1 or 12.2-1 for non building structures similar to buildings
seismic base shear, V
V = Cs W
seismic response coefficient (Cs)
Cs = Sds/(R/I) - ASCE 7 (12.8-2) non building structures (ie,, when T<Ts)
see page 1 - 89 for more Cs conditions
pg. 1 - 89
non building structures NOT similar to buildings
determine of seismic factors - R, Ω & Cd - Table 15.4 - 2 for non building structures NOT similar to buildings
seismic base shear, V
V = Cs W
seismic response coefficient, Cs
Cs = Sds / (R/I)
Cs shall not be less than:
Cs = 0.044 Sds I ≥ 0.03 minimum
In addition, for nonbuilding structures where S1 ≥ 0.6…. Cs shall not be less than:
Cs ≥ .08 S1 / (R/I) minimum * asce 7 15.4.1, item 2 for an exception for tanks and vessels