Design Reviewer (NBCP + Module) Flashcards
Gen Design Requirements
Ceiling height with natural ventilation
A. Less than 2.4m
B. Less than 2.7m
C. More than 2.1m
D. More than 2.4m
B. Less than 2.7m
Air space requirement per person
A. 14 cubic meters
B. 16 cubic meters
C. 17 cubic meters
D. 13 cubic meters
A. 14 cubic meters
Mezzanine floor ceiling height
A. 2.1m
B. 2.7m
C. 1.5m
D. 1.8m
1.8 meters
Attic opening in diameter
A. 600mm
B. 650mm
C. 550mm
D. 680mm
A . 600 mm
Attic minimum clear headroom above of access opening
A. 1.2m
B. 1.1m
C. 900mm
D. 800mm
800 mm
Draft stops shall be installed in all building exceeding _______?
A. 2500 sq m
B. 3000 sq m
C. 5000 sq m
D. 2000 sq m
2000 sq m
Roof drainage water from a building shall not be permitted to flow over public property, except for what group of occupancies?
A. A and H
B. A and C
C. A and J
D. A and E
C. Group A and J occupancies
Having an occupant load of more than 10 shall have at least ____ exits.
Two (2)
Every storey with an occupant load of 500-999 shall have at least ____ exits.
Three
Distance to exit without sprinkler system
45 m
Distance to exit with fire extinguishing system
60m
Minimum stairway width
Occupant load more than 50: ___
Occupant load of 50 or less: ____
Occupant load of less than 10:____
A. 1.2m , 0.95m , 0.75m
B. 1.1m , 0.90m , 0.75m
C. 1.1m , 0.90m , 0.70m
D. 1.2m , 0.90m , 0.70m
B.
more than 50: 1.1 meters
50 or less: 0.90 meters
less than 10: 0.75 meters
Maximum variation of riser and treads in any one flight
5mm
How many parking slot is required for R1 - R3 occupancies with 30 to 42 sq m GFA?
A. 1 every 6 lots
B. 1 every lot
C. 1 every 4 lots
D. 1 every 3 lots
C. 1 every 4 lots
Size of church per seat
- 6 sqm (altar, platform etc included)
2. 4 sqm (seating area only)
Theatre seating capacity can be estimated by diving the area by an occupant load of ____
0.65 sqm