DC GENERATORS Flashcards
1
Q
- The basic requirements of a DC armature winding is that it must be
A. A closed one
B. A lap winding
C. A wave winding
D. Either B or C
A
A. A close one
2
Q
- A wave winding must go atleast ____ around the armature before it closes back where it started.
A. Once
B. Twice
C. Thrice
D. Four times
A
B. Twice
3
Q
- The DC armature winding which coil sides are a pole pitch apart is called ____winding.
A. Multiplex
B. Fractional pitch
C. Full pitch
D. Pole pitch
A
C. Full pitch
4
Q
- For making a coil span equal to a pole pitch in the armature winding of DC generator, the back pitch of the winding must be equal to the number of
A. Commutator bars per pole
B. Winding elements
C. Armature conductors per path
D. Armature parallel paths
A
A. Commutator bars per pole
5
Q
- The sole purpose of a commutator in a DC generator is to
A. Increase output voltage
B. Reduce sparking at brushes
C. Provide smoother output
D. Convert the induced AC into DC
A
D. Convert the induced AC into DC
6
Q
- Lap winding is suitable for current, ___ voltage DC generators.
A. High, low
B. Low, high
C. Low, low
D. High, high
A
A. High, low
7
Q
- The series field of a short shunt DC generator is excited by ___ currents.
A. Shunt
B. Armature
C. Load
D. External
A
C. Load
8
Q
- In a DC generator, the generated emf is directly proportional to the
A. Field current
B. Pole Flux
C. Number of armature parallel paths
D. Number of dummy coils
A
B. Pole Flux
9
Q
- In DC generator l, armature reaction us produced actually by
A. It’s field current
B. Armature conductors
C. Field pole winding
D. Load current in armature
A
D. Load current in armature
10
Q
- In DC generator, the effect of armature reaction on the main pole Flux is to
A. Reduce it
B. Distort it
C. Reverse it
D. Both A and B
A
D. Both A and B
11
Q
- The most likely cause of sparking at the brushes in a DC machine is
A. Open coil in armature
B. Defective interpoles
C. Incorrect brush spring pressure
D. All of the above
A
D. All of the above
12
Q
- Shunt generator are most suited for suitable parallel operation because of their voltage characteristics
A. Identical
B. Dropping
C. Linear
D. Rising
A
B. Dropping
13
Q
Two parallel shunt generators will divide the total load equally in proportion to their kW output ratings only when they have the same
A. Rated Voltage
B. Voltage Regulations
C. Internal voltage drops
D. Both A and B
A
D. Both A and B
14
Q
- The voltage regulation if an overcompound DC generator is always
A. Positive
B. Negative
C. Zero
D. High
A
B. Negative
15
Q
- It has the poorest voltage regulation
A. Series generator
B. Long shunt compound generator
C. Shunt generator
D. Short shunt compound generator
A
A. Series generator