AC CIRCUITS ( THREE PHASE) Flashcards
- Theree wattmeter method is not used to measure power in a 3 phase circuit because…..
A. It is complicated
B. Generally neutral is not available or delta load cannot be opened
C. It requires three watt meters
D. None of the above
B. Generally neutral is not available or delta load cannot be opened
- The most difficult unbalanced 3 phased load to deal with is ….
A. 4 wire star connected unbalanced load
B. Unbalanced delta - connected load
C. Unbalanced 3 wire, Y- connected load
D. None of the above
C. Unbalanced 3 wire, Y- connected load
- The following are positive phase sequence except
A. ABC
B. CAB
C. BCA
D. CBA
D. CBA
- In a balanced three phase star connected circuit the line voltages are equal.
A. To the line current
B. To the phase voltage
C. And so are the line currents
D. But the line currenta are unequal
C. And so are the line currents
- The phase displacement between phasor in polyphase system is always?
A. 90 degrees
B. 120 degrees
C. 360 degrees divided by the number of phases
D. None of the above
C. 360 degrees divided by the number of phases
- In a star connected system line current is?
A. 0.707 times the phase current
B. 1.735 times the phase current
C. Equal to the phse current
D. 1.414 times the phase current
C. Equal to the phse current
- Power in a three phase delta system with balance load is equal to?
A. √3×VL×IL×pf
B. √3×Vph×Iph×pf
C. 3×Vph×IL×pf
D.3×VL×IL×pf
A. √3×VL×IL×pf
- In a delta connected system the libe current is?
A 1.414 times the phase current
B. Phasor sum of the two phase currents
C. Equal to the phase current
D. 1.732 times the phase current
D. 1.732 times the phase current
- Power in star connected system is?
A. Equal to that of delta system
B. √2 times the delta system
C. √3 times the delta system
D. 3 times of a delta system
A. Equal to that of delta system
- What is the minimum number of wattmeter required for measuring power of a three phase balanced load.
A. Two
B. Four
C. One
D. Three
C. One
- What is the minimum number of wattmeters required to measure unbalanced power for a thre phase system?
A. Two
B. Four
C. Theee
D. One
A. Two
- In two wattmeter method, the reading of the wattmeter will be identical when?
A. Load in one of the phases is zero
B. Power factor is unity
C. Power factor is 0.5
D. Neutral is carthed
B. Power factor is unity
- Power in a three phase star system is equal to?
A. √3×VL×IL×pf
B. √3×Vph×IL×pf
C. √3×VL×Iph×pf
D. 3×Vph×Iph×pf
D. 3×Vph×Iph×pf
- In 2 wattmeter method, the reading of one of the wattmeter will be zero when?
A. Power factor is unity
B. Power factor is 0.5
C. Load is one of the phases is zero
D. A neutral wire is not provided
B. Power factor is 0.5
- For an unbalanced 3 phase load, which connection is suitable?
A. 3 wire, open delta connection
B. 3 wire, delta connection
C. 4 wire, wye connection
D. 3 wire, wye connection
C. 4 wire, wye connection
- Minimum voltage regulation occurs when the power factor of the load is.
A. Unity
B. Lagging
C. Leading
D. Zero
C. Leading