Damage Control Programs Flashcards
Who is responsible for nominating a Damage Control Petty Officer (DCPO) within the division?
The Division Officer
Who is the final approval for nomination, replacement, and rotation of all DCPOs?
The Executive Officer
How long does a DCPO normally serve?
6 moths
What are the training requirements to be a DCPO?
DC Watchstander PQS 303 (Final Qualifier) Basic DC 301-306 (Pre-requisite) 301 Maintenance Man (Pre-requisite) 301 Craftsman (Pre-requisite) **RECOMMENDED COURSE**
What type of equipment is the DCPO responsible for within divisional spaces?
Watertight doors, valves, CO2/PKI/AFFF bottles, battle lanterns, deck drains
To whom does the DCPO report?
DCA
Which Navy Enlisted Classification (NEC) does the welding/brazing qualification program apply?
NEC U53A
What are the minimum criteria for the initial qualification and requalification of welders?
Initial: Complete HT “A” school or NEC U53A with passing grade of 75%.
Requal: Quarterly demos on test assembly, then VT through NDT. Annual vision test.
Who is responsible for maintaining an auditable file for each welder?
The Division Officer
What time of information is included in each welder’s file?
- Welder ID#
- Test date
- Qualification test # / process / position
- Test results
- Record of omission of space restriction
How often are audits of the welder/brazing qualification program required?
Annual
How many NDT methods are there and which are conducted by ships force onboard?
6; PT and VT
Which NDT method uses X-ray to show imperfections within the weld?
Radiographic Testing (RT)
How is the thickness of a weld measured with Ultrasonic Testing (UT)?
Sound waves are sent into the surface, the return is displays results w/ amplitude representing the thickness.
Magnetic Particle Testing (MT) is used to indicate imperfections in what part of a weld?
At or below the surface
How are cracks that are open to the surface indicated with Liquid Penetrant Testing (PT)?
A dye is applied to the surface and allowed to dry. Afterwards a developer is applied which will show imperfections, if any.
What is measured and inspected with visual and Dimensional Testing (VT)?
Inspects/measures specified dimensions to check for proper joint design and surface defects.
Which NDT method uses electromagnetic induction to detect and characterize surface and subsurface flaws in conductive materials?
Eddy Current Testing (ET)
What is the most widely used method of corrosion control?
Protective coatings (paint)
What is the purpose of the corrosion prevention and control program?
Track coating conditions, identify timely and appropriate maintenance decisions, and repairs to prevent system deficiencies IOT prevent a coating failure.
Which reference establishes the basic guidelines for the corrosion prevention and control program?
JFMM Volume VI
Which references provide specific guidance for inspection, prevention, and repair of corrosion onboard ships?
NSTM 100 and 631
What data is used to document coating systems inspections, maintenance, and repairs
Corrosion Control Information Management System (CSIMS)