D. Equipment and Facility Planning Flashcards
The practice of using human engineering to achieve an environmental design. The study of people’s efficiency in their working environment.
Ergonomics
**The planning process begins with a _______, which is a planning guide.
PROSPECTUS
The planning procedure begins with a prospectus, followed by organization of a _______ ______ (administrator, FS manager, architect, builder, equipment reps, mechanical engineer), conduction of a ________ study, and analysis of the ____.
The planning procedure begins with a PROSPECTUS, followed by organization of a PLANNING TEAM (administrator, FS manager, architect, builder, equipment reps, mechanical engineer), conduction of a FEASIBILITY study, and analysis of the MENU.
**The _____ determines space and equipment required.
MENU
Space required is determined by ____ ____ of foods purchased (raw, prepared).
Equipment required is determined by batch _____ and ______.
Space required is determined by MARKET FORM of foods purchased (raw, prepared).
Equipment required is determined by batch SIZE and FREQUENCY.
Walls must be of _______ _____, 5’8” high in food prep areas. Washable, impervious to moisture.
Glazed tile
Ceilings must be 14-__’ high, and a lighter color than walls.
14-18’
Floors must be ______, ______, and ______.
Durable, resilient, and non-slippery
_____ floors absorb grease, and are used in areas of light traffic - storerooms and receiving areas.
_____ ______ _____ or quarry tile floors are suitable for heavy traffic and are highly recommended for the kitchen.
Terrazzo and asphalt floors are used in the ______ _____.
Concrete floors absorb grease, and are used in areas of light traffic - storerooms and receiving areas.
Unglazed red clay or quarry tile floors are suitable for heavy traffic and are highly recommended for the kitchen.
Terrazzo and asphalt floors are used in the dining room.
Light intensity is measured in _____ _____.
Foot candles
Greater light intensity (__-__ foot candles) is needed in localized work areas (reading recipes).
General lighting (35-70 foot candles) in food prep and display areas.
Greater light intensity (70-150 foot candles) needd in localized work areas.
**The first step in planning is to plan the kitchen ON PAPER using a ____ ____. A typical foodservice design has little cross traffic and no backtracking.
**The first step in planning is to plan the kitchen ON PAPER using a flow chart.
________: pieces of paper cut to scale to represent pieces of equipment.
Helps visualize, plan and check for floorspace needed.
Template
Guidelines for spacing in the Cafeteria-
__ “ between chairs
__-__’ between tables
__’ serving width (4’ patron lane, 1’ tray slide, 2’ counter width, 4.5’ worker space, 2.5’ back bar
__’ per person employee dining
Guidelines for spacing in the Cafeteria-
18 “ between chairs
4-5’ between tables
14’ serving width (4’ patron lane, 1’ tray slide, 2’ counter width, 4.5’ worker space, 2.5’ back bar
12’ per person employee dining
Guidelines for spacing in the Kitchen-
__-__” 1 person lane
__-__” >1 person lane or mobile equipment passage
__” main traffic lane
__-__’ per bed floor area
__” heavy work counter height
__-__” light work counter height
Equipment must be __” off the floor for cleaning
__-__” clearance of heavy equipment from wall
Guidelines for spacing in the Kitchen-
36-42” 1 person lane
48-52” >1 person lane or mobile equipment passage
**60” main traffic lane
20-30’ per bed floor area
36” heavy work counter height
37-41” light work counter height
Equipment must be 6” off the floor for cleaning
12-24” clearance of heavy equipment from wall
**Main traffic lane in the kitchen should be __” wide.
**Main traffic lane in the kitchen should be 60” wide.
The _____ ______ is the best work area layout from a time and motion perspective.
Parallel and back-to-back parallel also very efficient.
U-shape large amount of surface area, but added steps walking in and out.
**Straight line best work area layout
Specifications for electrical equipment is in _____, watts, and type of current.
In _____ _____ _____ (BTU) for gas, and in _____ ____ _____ ____ (PSI) for steam.
Specifications for electrical equipment is in voltage watts, and type of current.
In BRITISH THERMAL UNITS (BTU) for gas, and in POUNDS PER SQUARE INCH (PSI) for steam.
**When ordering equipment, specifications include a _______ that states what will be covered and for how long.
Warranty
The National Sanitation Foundation International (NSFI) does VOLUNTARY inspection of _________.
The National Sanitation Foundation International (NSFI) does VOLUNTARY inspection of EQUIPMENT.
**Underwriter’s Laboratory (UL) does voluntary inspection of ________ _______.
**Underwriter’s Laboratory (UL) does voluntary inspection of ELECTRICAL EQUIPMENT.
**______ _______ is the best material for foodservice equipment. It is durable.
STAINLESS STEEL best material for foodservice equipment.
Gauge measures _______. The lower the gauge, the _____ the metal. 10-14 gauge most commonly used in equipment.
GAUGE measures WEIGHT. The lower the gauge, the STRONGER the metal.