CWP Flashcards
Aural Warning
Rotor below 360
Rotor above 410
Hyd pressure below 30 bar
Red lights (immediate action)
HYD FIRE MGP P MGP T ENG P
HYD
Pressure less than 30 bar
Do not press HYD Test
Airspeed set 40-60 kts HYD off Run on landing LOCK collective on ground Shutdown
MGP P
Reduce power land as soon as possible
MGP T
Test CWP panel
If no light, (bulb out) land as soon as possible
If light, land and check MGP oil level, if normal fly to nearest base
ENG P
Reduce power, check oil pressure indicator
If oil pressure is low check torque,
If both pressure and torque are correct land as soon as possible, otherwise land immediately.
GEN
Check pushbutton, attempt to reset If unsuccessful, shed consumer circuits and watch voltage (22 min) Keep fuel pumps on Day 50 min on battery Night 20 min on battery
BATT
Check pushbutton
Continue flight
FUEL
18 min at MCP
PITOT
Check pushbutton, monitor Airspeed indicator
DOORS
Reduce airspeed 120 knots
Amber Lights
ENG Chip F FILT CHIP TGB CHIP MGB FUEL P
ENG CHIP
Land as soon as possible
It is prohibited to take off again unless Maintenance manual checks have been performed
F FILT
Reduce engine power
If light goes out, continue flight
If light remains on, land as soon as possible
CHIP TGB
Continue flight avoiding prolonged hovering