CT 1 Flashcards

1
Q

Adv of CT over Plain film X-ray

A

Reduced SuperImposition
Better Contrast
Single Breadth volume scans
Multi planar imaging

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

DisADV. of CT over Plainf Film X-ray

A

Lower spatial res
higher dose
more artifacts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Why does CT have a lower spacial res?

A

Lower FDD

Lower ODD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Typical CT range and values for water, air and bone

A

-1024 - +3071
Air: -1000
Water: 0
Bone: +1000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which CT gen introduced fan beam tech?

A

2nd

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which CT gen introduced 360 rotation AND curved detectors?

A

3rd

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which CT gen introduced DSCT (dual source CT) and what was it mainly used for scanning?

A

6th - 2x Xray tubes.

Cardiac CT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Why did 7th Gen have a lower contrast?

A

Used flat panel detectors over multidetectors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What CT gen is helical scanners based on?

A

3rd

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What technology allows for continuous gantry rotation?

A

Slip ring

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is Spiral width dependent on?

A

Patient and X-ray movement speed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What will a wider spiral width cause?

A

LOWER spatial and contrast res

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What beam does a multi-slice CT scanner use?

A

CONE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Why does a table have a low µ?

A

A high Z would increase patient does (plus increase noise).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the purpose of a bow tie filter?

A

Counteracts beam hardening by attenuating the beam more at the periphery as opposed to the centre. Resulting in a more ‘uniformed’ beam.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Purpose of Pre-collimation?

A

Adjust FSS and Pneumbra

17
Q

Purpose of post-collimation

A

Shape beam and scatter reduction

18
Q

What DETERMINES slice thickness?

A

collimation of incident beam.

19
Q

A larger slice has a better contrast res + SNR, but what happens to spatial res?

A

Decrease.

20
Q

What effect does SNR have on contrast and spatial res?

A

Contrast will increase with SNR

Spatial will Decrease with SNR

21
Q

What 2 factors effect pitch?

A
Slice thickness (in single-slice)
Beam Thickness (in multi-slice)