Condensate Demin Flashcards

1
Q

Demin Limitations

A

Resin Trap - 18(20)
“E” valve - 59.5(60)psig
System - 53(50)psig
Vessel - 22psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Flow Balance Limits

A

<500gpm between vessels
>50(40)psig CBP suction pressure
Controls 1000-4500gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Max flow through a Demin

A

4800gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Number of Demin vessels

A

7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Purpose of Demin System

A
  • Removes suspended solids

- Maintains adequate PH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When are additional vessels placed into service

A

Minimum of 2 on startup and additional vessels placed into service prior to exceeding 4300gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Limits for manually removing and Backwashing Vessel

A
  • Vessel dp - 22psid
  • System dp - 53(50)
  • As determined by SS
  • Not balanced within <500gpm
  • Low Demin efficiency (Chem)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly