Comeng Traction Revision Flashcards
When might the LP flag raise?
*When MR falls to below 500
*When EP/Rheo Brake is switched out or loss of power to the lock out magnet valve
*when bvics is closed
* if EP or MA isolate is closed
What are the 3 extra reservoirs on a KNORR?
Pre control
Ep
Supplementary
What does the brake pipe test switch do when it is in and the bell button is pressed?
Activates a reduction in BP
What is the purpose of the traction overload button?
Resets tripped overloads in traction system when traction motors fail to power or Rheo brake
What gauges are located on the drivers dash?
Brake cylinder
Duplex gauge: MR red, BP white
Speedo
Amps
Control Res
For train lined/remote Panto up and down buttons to operate, what power voltage must be available?
110vDC
When is the control gov bypass used?
When operating train with RED EC isolated
Which light on the faults status panel will illuminate to indicate that 110vDC is available?
Dc supply Light
If the local and or line switch lights are illuminated, what equipment has a fault?
Traction
What is the main switch for?
Isolates 1500vdc to the line breakers
What do bogie isolating cocks do?
Isolate air from brake unit to the brake cylinders
What is the input and output for the MA?
INput 1500DC
Output 415 AC
What equipment has an input of 1500DC?
MA,
Air compressors
Traction equipment
What equip does the MA power?
Air cons
Saloon lights
Traction cooling fan
What are the resets on the MA for?
To reset MA in the event of it over speeding
What are the auxiliary reservoirs for?
Store air for applying air brakes
Under normal stabling conditions, how long will the stabling light flash for after lowering the panto’s?
15 min
What are the 3 electrical isolate toggles on the right hand wall of driver dash for?
Local Panto
RHEO
MA
What isolates are in the footwell of the drivers seat?
Uncouple
Whistle
Vicers
What does bvics control the flow of?
*Main res air to brake controller to charge brake pipe
* electricity to EP/RHEO, LP FLAG AND LOCK OUT MAGNET, door monitoring circuit (door closed light)
What are the 3 requirements to reset vicers and stop exhausting BP air after activation?
Speed at 0km
BP below 25kpa
Wait 10 seconds
When is the DDU active?
When bvics open
One Panto up
One MA on
After closing bvics, how long will DDU retain the TDN info?
3 min
If the red EC cock is turned to isolate,
What equipment is introduced?
The secondary safety circuit which includes FEEC:
Foot pilot valve
Emergency pilot valve
Emergency control gov
Control gov bypass
When on the secondary circuit, how do you charge the BP?
Must have foot pilot valve set and press control gov bypass button