CIW Chapter 10 Flashcards

1
Q

A ___ material is a material that is subject to easy ignition and capable of rapid flaming.

A

flammable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The time required for sealing compounds to dry and harden varies, but typically averages about ___ minutes.

A

60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The basic unit of a solar PV system is a(n) ___.

A

module

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Service drop conductors (under 600 V) must have a(n) ___’ clearance over public streets, alleys, roadways, parking areas subject to truck traffic, and nonresidential driveways.

A

18

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Most agricultural and food processing facilities are classified as Class ___, Division ___.

A

II; 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A(n) ___ transfer switch is a switch that is used to monitor equipment attached to a utility line and switch the power source automatically if the primary source of current fails.

A

bus or power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A(n) ___ apparatus receives a continuous flow of clean air through equipment.

A

purged and pressurized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Holiday decorative lighting can be installed for a period of ___ days only.

A

90

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Areas directly adjacent to Class I, Division 1 areas are normally classified as Class ___, Division ___ locations.

A

I; 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A(n) ___ program is a written procedural program of tests used to verify the integrity of the EGC in receptacles used in temporary power, extension cords, and portable corded power tools.

A

assured equipment grounding conductor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A(n) ___ grounded system is a wiring system that requires two separate ground paths for fixed electrical equipment and receptacles in patient care areas.

A

redundant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A processing area within a paper mill is classified as a Class ___, Division ___ location.

A

III; 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Most portable tools commonly use ___ V, ___-phase power

A

120; single

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Conductors from a generator to the first distribution device containing overcurrent protection must be sized at ___% or more of the nameplate amperage rating of the generator.

A

115

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A ___ is a classification for an atmosphere that contains a certain type of flammable material.

A

class

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Voltage drop from the beginning of the branch circuit to where the load receives its power must be no more than ___%.

A

5

17
Q

A(n) ___ branch is a branch of an electrical distribution system that supplies systems related to occupant safety in the case of an emergency.

A

life safety

18
Q

___ is the undesirable condition where a local power source continues to transfer power to the utility grid during a utility outage.

A

Islanding

19
Q

Most permanently installed generators supplying industrial facilities are rated ___ MW or higher.

A

2

20
Q

A(n) ___ system is a renewable energy system that operates in parallel with, and is connected to, the electric utility grid.

A