CID Chapter 11 Flashcards

1
Q

A(n) ___ cable is a cable that is used to transmit high-frequency signals and consists of a central copper conductor surrounded and held in place by an insulator, which is then covered with a braided conductor shield.

A

Coaxial

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Holes are drilled in the bottom of the duct to accommodate a(n) ___ that senses the presence of smoke and an exhaust tube that removes air that has been circulated through the inlet tube.

A

inlet tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A good signal reading on a fiber optic connector is dependent on the ___.

A

quality of the polish

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The “8P” designated plug and connector indicates there are 8 ___.

A

positions for conductors across the width of the device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A(n) ___ entrance provides a pathway for conduit, cable trays, and sideways for both communication and power circuits.

A

tunnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A(n) ___ circuit connects visual and/or audible alarm devices to a fire alarm system.

A

notification appliance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The ___ publishes ANSI-approved standards regarding the performance specifications of telecommunications and electronics systems.

A

NECA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A ___ is an opening through a barrier, such as a wall, to allow the passage of pathways, raceways, cables, piping, ductwork, and other such systems.

A

penetration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A(n) ___ IDC block uses silver-plated IDC contacts to provide electrical terminations.

A

LSA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

___ is constructed for non-power-limited fire alarm circuits and designed so as not to require its installation in a raceway except in certain applications, and can be suitable for use in plenums.

A

Non-power-limited fire cable—plenum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Visible notification appliances must. be installed a maximum distance of ___’ from the end of a corridor and spaced a maximum distance of ___’ apart within the corridor.

A

15, 100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A(n) ___ circuit is connected to a fire alarm control panel at only one end of the circuit and uses an end-of-line device (resistor or relay) at the other end.

A

class B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Smoke detectors mounted on walls must be a minimum distance of ___” from ceilings.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Most copper installations consist of CAT ___ cabling.

A

5e

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A(n) ___ is a short-distance data communication network for a specific user group throughout a group of interconnected computers that share common applications, data, and peripheral devices.

A

local area network (LAN)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

An equipment rack is a vertical metal frame rack installed to support larger structured cabling equipment and components and is also referred to as a(n) ___.

A

cable management system

17
Q

A(n) ___ is hard-wired telephone service that provides service to single-line telephone systems.

A

plain old telephone service (POTS)

18
Q

A ___ converts sound pressure waves into a modulated current signal.

A

handset transmitter

19
Q

Installed equipment racks must have a clearance of ___” front and back.

A

36

20
Q

A ___ contains connecting hardware used to patch between groups of cables and equipment.

A

patch panel

21
Q

A(n) ___ serves as the main collection point for a telecommunications system’s grounding system.

A

primary bonding busbar (PBB)

22
Q

___ is the process of installing engineered materials or devices as a barrier in an architectural structure to prevent the passage of flames, liquids, or gases through the barrier.

A

Firestopping

23
Q

A(n) ___ system automatically controls functions such as heating, cooling, and ventilation (HVAC), lighting, security, process control, and fire/heat detection and alarm.

A

building automation

24
Q

A(n) ___ plug is adopted by the Federal Communications Commission (FCC) as the standard interface for telephone and data equipment for public network.

A

modular

25
Q

Horizontal cabling runs in work areas have a maximum distance of ___m.

A

90