City Gas Flashcards
The Washington gas company provides pilot relighting for gas appliances (true/false)
False
Emergencies are classified in 4 situations (what are the four)
Gas escaping outside
Gas burning outside
Gas escaping inside
Gas burning inside
Natural gas is heavier or lighter than air?
Lighter
The ignition point of natural gas
1100-1200 degrees
Natural gas burning outside, do not extinguish the fire (true/false)
True
Residential gas meters located outside the building wall have a service main from underground and _____ stopcock just ahead of the meter/regulator
1
The stopcock may have a __________ shaped nut
Pentagonal
Turn the stopcock crosswise to the gas pipe _______of a turn clockwise or counterclockwise
1/4 turn
Turning the stopcock more the 1/4 will allow gas to continue to flow (true/false)
True
The fire valve has a raised operating stem that’s inside a ______ inch pipe
2 1/2”
The fire valve projects ______inches above grade
12”
Remove the cap on the fire valve with a fire plug wrench by turning it __________
Counterclockwise
Curb gate valve, turn the hand wheel or ______ inch square operating head __________ until the valve resists
2”
Clockwise
How many turns to turn off the curb gate valve?
6-20
The curb gate valve shutoff is sometimes used in lieu of a fire valve with written approval from who?
Dc fire marshal