goniometer:
measurement instrument for evaluating joint range of motion: accuracy is ensured through following standardized procedures including
client position
positioning of the instrument
normal range of motion for the cervical spine
degrees of measurement include:
flexion 0-45
extension: 0-45
lateral flexion: 0-45
rotation: 0-60
ROM thoracic and lumbar
flexion: 0-80
extension: 0-30
lateral flexion: 0-40
rotation: 0-45
ROM shoulder:
flexion: 0-170
extension: 0-60
horizonational ABduction: 0-40
horizontal adduction: 0-130
internal rotation:0-70
external rotation: 0-90
ROM elbow and forearm
flexion: 0-135/150
supination: 0-80/90
pronation: 0 -80/90
ROM wrist:
flexion: 0-80
extension: 0-70
ulnar deviation: 0-30
radial deviation: 0-20
ROM thumb:
MP flexion: 0-90
IP Flexion: 0-80/90
ABduction: 0-50
ROM fingers:
MP flex: 0-90 MP hyperextension: 0-15/45 PIP flex: 0-110 DIP flex: 0-80 ABduction: 0-25
ROM hip:
flex: 0-120
ext: 0-30
AB: 0-40
add: 0-35
IR: 0-45
ER: 0-45
ROM knee:
flexion: 0-135
ROM: ankle and foot
plantar flex: 0-50
dorsiflexion: 0-15
inversion: 0-35
eversion: 0-20
manual muscle testing:
structured approach to measure muscle strength adn apply a muscle grade to the maximal effort put forth :
grading scale range: 0-5 to normal 5/5
muscle grade 0/5
no active movement noted
no muscle contraction observed or palpated
muscle grade 1/5
trace movement observed and palpated
no active movement noted, but muscle contraction is observed or palpated
muscle grade 2/5
poor strength observed where movement is noted only in a gravity minimized plane
2- / 5 MMT
able to initiate movement in gravity-minimized plane
2 / 5
poor: incomplete ROM in gravity minimized plane
2 + / 5
complete ROM in gravity minimized plane
muscle grade 3 /5
assigned for: fair strength observed where movement isn noted against graviety
3 - / 5
incomplete ROM against gravity
3 / 5
full ROM against gravity with no resistance applied
3 + / 5
full ROM against gravity and slight resistnace