Q

All fittings that are not clearly identifiable should be

A

Rejected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

All markings shall be legible and must have the following requirements

A

Manufacturers name or trademark
Service designation
Material designation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Steam boiler fittings are defined as

A

Devices directly attached to the pressure part of the boiler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Three methods of testing the accuracy of a pressure gauge is

A

Test gauge comparison
Dead-weight tester
Hydraulic comparator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is test gauge comparison

A

Attaching an accurate gauge to a boiler while in operation to compare the accurate gauge with the gauge being tested

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

An essential fitting between the boiler and the steam pressure gauge is

A

A siphon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A steam pressure gauge may be graduated in

A

Kilo pascals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The scales on a pressure gauge for a steam heating boiler shall be graduated between one of the following

A

200 to 414 Kpa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

An inspectors test connection is

A

No mandatory on lp boilers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When installing a siphon it

A

Should be first filled with water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When using a dead weight tester, the effect of friction

A

Is reduced by rotating the platform

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The working medium in the dead weight tester is

A

Medium weight oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Hydraulic comparators, which are used for testing gauges, rely on the accuracy of the

A

Master gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

On a multiple steam heating system, a stop valve must be placed attach boiler outlet to

A

Allow boiler isolation from the system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

On low pressure steam boilers, the boiler outlet valves are ussually

A

Gate valves because of there low resistance to flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

An outside screw and yolk valve

A

Readily shows its operating position

17
Q

A boiler feed water stop valve

A

Is used to isolate the feedwater line

18
Q

A globe valve should be used in the feedwater line

A

At all times

19
Q

A stop valve is fitted between the boiler and the feed water check valve

A

For isolation and to provide a positive shutoff

20
Q

Boiler foaming may be a result of

A

High TDS

21
Q

Boiler blowdown lines have a specific size range based on

A

Boiler capacity

22
Q

Boiler blowdown piping must be

A

Full size to the point of discharge

23
Q

A steam boiler is blown down in order to

A

Discharge sediment and scale forming matter from the boiler

24
Q

A steam boiler is blown down in order to

A

Discharge sediment and scale forming matter from the boiler

25
Q

The purpose of the small vent valve or cock located on top of the shell or on top of the water column on most boilers

A

To allow air to escape from the boiler when the boiler is being filled with water

26
Q

When the steam outlet is 51mm pipe size or larger, it is recommended that a ___________ valve with a rising stem a used

A

OS&Y

27
Q

What fitting is required in the feedwater line adjacent to the boiler before the stop valve?

A

Check valve

28
Q

A function of the bourdon tube hairspring is to

A

Eliminate backlash or play in the pointer

29
Q

An essential fitting between the boiler and the steam pressure gauge is the

A

Siphon

30
Q

According to ASME code section IV, steel or wrought iron pressure gauge connections are to be a minimum of ______ mm in pipe size

A