Chapter 7 - comparing mass analyzers Flashcards

1
Q

Double focusing resolving power

A

≈100,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Double focusing mass accuracy

A

< 1 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Double focusing mass range

A

5-15,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Double focusing linear dynamic range

A

109

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Double focusing acquisition mode

A

fg (full scan)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Double focusing pressure

A

10-7 mbar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Double focusing sampling

A

Continuous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

TOF resolving power

A

>40,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

TOF mass accuracy

A

< 1 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

TOF mass range

A

5-40,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

TOF linear dynamic range

A

106

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TOF acquisition mode

A

pg (full scan)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

TOF pressure

A

10-7 mbar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

TOF sampling

A

Pulsed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Quadrupole resolving power

A

unit resolution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Quadrupole mass accuracy

A

0.1 Da

17
Q

Quadrupole mass range

A

5-2000

18
Q

Quadrupole linear dynamic range

A

106

19
Q

Quadrupole acquisition mode

A

fg-pg (SRM)

20
Q

Quadrupole pressure

A

10-6 mbar

21
Q

Quadrupole sampling

A

Continuous

22
Q

Quadrupole ion trap resolving power

A

Unit resolution

23
Q

Quadrupole ion trap mass accuracy

A

0.1 Da

24
Q

Quadrupole ion trap mass range

A

5-2,000

25
Q

Quadrupole ion trap linear dynamic range

A

106

26
Q

Quadrupole ion trap acquisition mode

A

fg-pg (SRM)

27
Q

Quadrupole ion trap pressure

A

10-3 mbar

28
Q

Quadrupole ion trap sampling

A

Pulsed

29
Q

Orbitrap resolving power

A

>140,000

30
Q

Orbitrap mass accuracy

A

< 1 ppm

31
Q

Orbitrap mass range

A

50-6,000

32
Q

Orbitrap linear dynamic range

A

104

33
Q

Orbitrap acquisition mode

A

fg-pg (full scan)

34
Q

Orbitrap pressure

A

10-9 mbar

35
Q

Orbitrap sampling

A

Pulsed