Chapter 4 Flashcards
Field Measurements
define structure to electrolyte potential
The potential difference between the surface of a buried or submerged metallic structure and the electrolyte that is measured with reference to an electrode in contact with the electrolyte.
to minimize IR drop the reference electrode should be placed________
as close to the structure as possible.
__________ are computerized instruments by which data is taken by an integrated meter such as a voltmeter an the reading is then stored in a memory
data logger
shunts
used as a method of calculating current by measuring the voltage drop across a known resistance and calculating the current.
A functioning diode will typically display a voltage from
_______ to _______ in the forward bias and ______ in the verse bias.
0.3 V to 0.9V and OL
for shorted diodes the meter will display
low voltage at both ends
For open circuit diodes the meter will display ____ at both ends.
OL