The voids in CMUs are called?
cells
The nominal length of typical CMU is?
16in.
The nominal height of typical CMU is
8in.
The nominal width of typical CMU is:
a. 18in.
b. 16in.
c. 12in.
d. 8in.
e. variable
e. variable
A typical CMU has:
a. one web
b. two web
c. three webs
d. four webs
e. five webs
c. three webs
A typical CMU has:
a. one face shell
b. two face shells
c. three face shells
d. four face shells
e. five face shells
d. four face shells
Which of the following CMU shapes is used to simulate a stack-bond wall, although the wall, in fact, made with a running-bond pattern?
a. Lintel
b. bullnose unit
c. sash unit
d. unit with projection face shells
e. scored unit
e. scored unit
Which of the following CMU shapes has a rounded corner?
a. lintel
b. bullnose unit
c. sash unit
d. unit with projecting face shells
b. bullnose unit
CMUs with projecting face shells can be used on both sides of a control joint in a wall. The other unit that is commonly used in the same situation is a:
a. scored unit
b. bullnose unit
c. sash unit
d. intel unit
c. sash unit
Which of the following CMU shapes has U-shaped profile in its vertical cross section?
a. Lintel unit
b. bullnose unit
c. Sash unit
d. Unit with projecting face shells
e. scored unit
a. Lintel unit
Arching action occurs in a masonry wall with:
a. a running-bond pattern
b. stack-bond pattern
c. both (a) and (b)
d. neither (a) nor (b)
a. a running-bond pattern
A lintel over an opening in all masonry walls is designed to carry the load from triangle-shaped superimposed masonry. True or False
False
If a CMU wall is vertically reinforced at 16in. on centers, which of the following units will you recommend for use in the wall?
a. A-unit
b. H-unit
c. Standard unit with three webs
d. sash unit
e. Bond beam unit
A. A-unit
If a CMU wall is vertically reinforced at 8in. on centers, which of the following units will you recommend for use in the wall?
a. A-unit
b. H-unit
c. Standard unit with three webs
d. Sash unit
e. Bond beam unit
b. H-unit
If a CMU wall is vertically reinforced at 24in. on centers, which of the following units will you recommend for use in the wall?
a. A-nit
b. H-unit
c. Standard unit with three webs
d. Both (a) and (b)
e. Both (a) and (c)
e. Both (a) and (c)