Chapter 2 Electrical systems Operations and Maintenance Flashcards
Building manager Tom is concerned with holding voltages to close tolerances in order to achieve:
a. harmonics
b. clean power
c. an uninterruptible power supply (UPS).
d. power during power outages.
b. clean power
Max is having an uninterruptible power supply (UPS) system installed in the facility. The main reason for such a system is to:
a. supply generally clean AC.
b. Supply generally clean DC.
c. maintain a constant voltage and frequency.
d. maintain power during power outages.
d. maintain power during power outages.
The technician is dealing with a problem of harmonics. Harmonics are distortions of _____ in an electrical system.
a. current but not voltage
b. voltage but not current
c. both current and voltage
d. neither current nor voltage
c. both current and voltage
John is managing the renovation of his building’s equipment. the Facility designer has calculated that the max short circuit that could occur for a panel is 14, 000 amperes. which of the following rated circuit breakers would not protect the panel against a fault current
a. 10,000 amperes
b. 14,000 amperes
c. 25,000 amperes
d. 65,000 amperes
a. 10,000 amperes
If a buildings power factor is not within the acceptable levels established by the utility, a property manager may have to install equipment to ______ the power factor rating.
a. increase
b. decrease
c. sustain
d. stop
a. increase
If the property manager were in charge of a _____, he might find it more economical to have on-site power generation.
a. residential complex
b. small retail store
c. multi-building college campus
d. typical urban office building.
c. multi-building college campus
If Diane is to engage in switch-gear maintenance, which of the following steps would she not perform?
a. cleaning
b. excercising
c. testing
d. valuing
d. valuing
To improve the reliability of transformers, the most important maintenance function is to continuously remove________
a. coolant
b. heat
c. dust
d. energy
b. heat
Because larger generation and distribution facilities are needed to compensate for reduced ssystem efficiency, the property manager can expect _____ charges from the utility company.
a. power factor
b. time of use
c. fuel adjustment
d. miscellaneous
a. power factor
a _____ is preferred by many property and facilities managers because it does not include any demand charge.
a. three part rate
b. block meter rate
c. step-meter rate
d. straight-line meter rate
b. block meter rate