Chapter 15 Quiz Flashcards
The commercial fluoroscope was developed by:
a.) newton
b.) rutherford
c.) einstein
d.) edison
d.) edison
The newest fluoroscopy systems use a flat panel detector
a.) to record the overhead images following fluoroscopy
b.) in addition to the image intensifier
c.) to record the spot images during fluoroscopy
d.) in place of the image intensifier
d.) in place of the image intensifier
A loss of brightness around the edge of the fluoroscopic image caused by the curve of the photocathode is:
a.) pincushion appearance
b.) vignetting
c.) magnification
d.) noise
b.) vignetting
Amorphus selenium is used as the:
a.) photodetector for direct capture DR imaging
b.) photoconductor for indirect capture DR imaging
c.) photoconductor for direct capture DR Imaging
d.) photodetector for indirect capture DR imaging
c.) photoconductor for direct capture DR imaging
Quantam mottle, or noise, occurs beacause of what?
insufficient mas
This part of the image intensifier absorbs light and produces electrons.
a.) output phosphor
b.) input phosphor
c.) photocathode
d.) electrostatic focusing lens
c.) Photocathode
In an indirect capture DR system, the electronic components that are configured in a network of detector elements is the:
a.) charge coupled device (CCD)
b.) scintillator
c.) photoconductor
d.) thin film transistor
d.) thin film transistor
Which of the following is/are associated with magnification in fluoroscopy?
1.) increased mA
2.) smaller portion of the input phosphor is used
3.) image intensifier focal point moves closer to the output phosphor
a.) 2 and 3 only
b.) 1 only
c.) 1 and 2 only
d.) 1, 2 and 3 only
c.) 1 and 2 only
Distortion of the fluoroscopic image that appears as unequal magnification is:
a.) magnification
b.) pincushion appearance
c.) vignetting
d.) noise
b.) pincushion appearance
In mobile fluoroscopy, the closer the image intensifier to the patient, the higher the patient dose.
a.) true
b.) false
b.) false
Flat panel detectors for fluoroscopic imaging can be the:
a.) amorphous selenium direct capture detector
b.) cesium iodide amorphus slicon indirect capture detector
c.) amorphus silicon direct capture detector
d.) a and b
d.) a and b
A common site for mobile fluoro is:
in the OR
In radiographic image intensification, the ratio of the number of light photons at the output phosphor to the number of photons at the input phosphor describes.
a.) brightness gain
b.) flux gain
c.) conversion factor
d.) minification gain
b.) flux gain
A disadvantage of using magnification mode during fluoroscopy using an image intensifier is:
a.) the patient receives additional dose
b.) none of the above
c.) the image brightness is inconsistent
d.) the image has less resolution
a.) the patient receives additional dose
The purpose of the 5 minute timer in fluoro is:
a.) terminate exposure once the maximumtime has been reached
b.) inform the radiographer of equipment malfunction
c.) open the circuit
d.) alert the radiographer
d.) alert the radiographer