Chap 4 (flashcards)
The grade away from foundation walls shall fall a minimum of _______ inches within the first ______ feet.
6 inches (and) 10 feet
R401.3 Drainage
In Seismic Design Categories D0, D1 and D2, foundations with stem walls shall be provided with a minimum of one No. ____ horizontal bar within 12 inches of the top of the wall and one No. _____ horizontal bar located 3 to 4 inches from the bottom of the footing.
4 (and) 4
R403.1.3.1 Concrete stem walls with concrete footings
All exterior footings shall be placed at least _____ inches below the undisturbed ground surface.
12 inches
Where applicable, the depth of footings shall also conform to Sections R403.1.4.1 and R403.1.4.2
R403.1.4 Minimum depth
The top surface of footings shall be level. The bottom surface of footings shall not have a slop exceeding _____ unit vertical in _____ units horizontal.
1 unit (and) 10 unit
(1:10, 10% slope)
R403.1.5 Slope
Wood sill plates shall be anchored to the foundation with anchor bolts spaced a maximum of ______ feet on center.
6 feet
R403.1.6 Foundation anchorage
Foundation anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of _____ inches into concrete or grouted cells of concrete masonry units.
1/2 inch (and) 7 inches
R403.1.6 Foundation anchorage
Isolated hollow masonry piers shall have a minimum nominal thickness of _____ inches.
8 inches
R404.1.9 Isolated masonry piers
Hollow masonry piers shall be capped with _______ inches of solid masonry or concrete or a masonry cap block.
4 inches
As an alternative, the cavities of the top course must be filled with concrete or grout.
R404.1.9.1 Pier cap
The studs used in wood foundation walls shall be ____ -inch by ______ -inch members.
2 inch by 6 inch
R404.2.2 Stud size
Wood sill plates shall be a minimum of ____ -inch by ______ -inch nominal lumber.
2 inch by 4 inch
R404.3 Wood sill plates
Unless otherwise recommended by the drain manufacturer, perforated foundation drains shall be surrounded with an approved _______ ________.
filter membrane
Or the filter membrane shall cover the washed gravel or crushed rock covering the drain.
R405.1 Concrete or masonry foundations
Steel pipe columns shall be not less than ______ inches in diameter
3 inches
R407.3 Structural requirements
In under-floor spaces, the minimum net area of ventilation openings shall be not less than ______ sqft for each _______ sqft of under-floor space area.
1 sqft (and) 150 sqft
R408.1 Ventilation
Ventilation openings in under-floor spaces are not required where the ground is covered with a continuous ______ vapor retarder and the joints overlap at least _____ inches.
Class I (and) 6 inches
R408.3 Unvented crawl space
The minimum required floor access opening to all under-floor spaces shall be ______ inches by _________ inches.
18 inches by 24 inches
R408.4 Access