CH13 A330 HYD Flashcards
HYD_01 Understand the control functions and indications on the HYD panel.
1. ELEC ON Pbs
- AUTO (green and yellow) (lights out) - Electric hydraulic pump runs ________:
- Green - One engine ________ when the landing gear is selected UP (runs for _____ seconds).
- (to assist in gear retraction - not LOD)
- Yellow - Engine 2 ________ and flaps lever not at ________and ________ electric pump not running (runs until shut off).
- (To assist in flap retraction - not LOD)
- Yellow pump also runs ________ during cargo door operation.
- Green - One engine ________ when the landing gear is selected UP (runs for _____ seconds).
- STBY (blue) (lights out) - Blue pump runs automatically with ENGINE _____ failure together with a ______ 1 OR _____ 3 fault. (to assist in rudder control -not LOD)
- ON - Illuminates blue if the respective electric pump is activated ______ or ______.
Not LOD info from CORE HYD Part 3 Section 4 Elect driven :57 remaining
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
1. ELEC ON Pbs
- AUTO (green and yellow) (lights out) - Electric hydraulic pump runs automatically:
- Green - One engine failure when the landing gear is selected up (runs for 25 seconds).
- Yellow - Engine 2 failed and flaps lever not at zero and green electric pump not running (runs until shut off).
- Yellow pump also runs automatically during cargo door operation.
- STBY (blue) (lights out) - Blue pump runs automatically with engine 1 failure together with a PRIM 1 or PRIM 3 fault.
- ON - Illuminates blue if the respective electric pump is activated automatically or manually.
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
2. ELEC OFF Pbs
- Lights out - Manual and automatic operation of the respective pump is ________.
- OFF - Manual and automatic operation of the respective pump is ________.
- FAULT - Illuminates amber if any of the following conditions are met:
- The reservoir ________ level is ________.
- Reservoir ________ pressure is low.
- Pump ________ is low.
- The reservoir _______._
- The ________ overheats.
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
2. ELEC OFF Pbs
- Lights out - Manual and automatic operation of the respective pump is available.
- OFF - Manual and automatic operation of the respective pump is inhibited.
- FAULT - Illuminates amber if any of the following conditions are met:
- The reservoir fluid level is low.
- Reservoir air pressure is low.
- Pump pressure is low.
- The reservoir overheats.
- The pump overheats.
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
3. ENG 1(2) Pbs
- On (lights out) - The respective engine driven pump operates ________
- OFF - The pump continues to be turned by its respective engine but is______and does not provide hydraulic power.
- FAULT - Illuminates amber if any of the following conditions are met:
- The reservoir ________ level is _______._
- Reservoir ______ ______ is low.
- The reservoir _______._
- Pump ________ is low (inhibited on the ground when the engine is ________).
The FAULT light extinguishes when the pb is selected ________.
- However, in the case of a ______ ______, the FAULT light will remain illuminated as long as the overheat condition exists.
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
3. ENG 1(2) Pbs
- On (lights out) - The respective engine driven pump operates normally.
- OFF - The pump continues to be turned by its respective engine but is depressurized and does not provide hydraulic power.
- FAULT - Illuminates amber if any of the following conditions are met:
- The reservoir fluid level is low.
- Reservoir air pressure is low.
- The reservoir overheats.
- Pump pressure is low (inhibited on the ground when the engine is stopped).
The FAULT light extinguishes when the pb is selected OFF.
- However, in the case of a reservoir overheat, the FAULT light will remain illuminated as long as the overheat condition exists.
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
4. RAT MAN ON Pb
- Pushed (guard lifted) - Extends the RAT ________._
VOL. II, 29.3.3
HYD_01 Understand the control functions and indications on the HYD panel.
4. RAT MAN ON Pb
- Pushed (guard lifted) - Extends the RAT manually.
VOL. II, 29.3.3
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
1. Distribution Triangles
- Displayed in open green when hydraulic ________ rises above a predetermined pressure.
- Becomes amber if the pressure in the respective system ________ below a predetermined pressure.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
1. Distribution Triangles
- Displayed in open green when hydraulic pressure rises above a predetermined pressure.
- Becomes amber if the pressure in the respective system decreases below a predetermined pressure.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
2. System Labels
- Displayed in white when hydraulic pressure _______ above a predetermined pressure.
- Becomes amber if the pressure in the respective system ________ below a predetermined pressure.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
2. System Labels
- Displayed in white when hydraulic pressure rises above a predetermined pressure.
- Becomes amber if the pressure in the respective system decreases below a predetermined pressure.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
3. Hydraulic Pressures
- Displayed in green if the pressure ___ __ or _____ a predetermined pressure
- and amber if it is ________.
An exception to these presentations is when the________ electric pump is running during cargo door operation.
- The hydraulic pressure indication will be normal (green) while the pump is ________;
- however, the YELLOW system ________ and distribution ________ will be displayed in amber.
- This indicates that the yellow system is only ________ powered.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
3. Hydraulic Pressures
- Displayed in green if the pressure is at or above a predetermined pressure
- and amber if it is below.
An exception to these presentations is when the yellow electric pump is running during cargo door operation.
- The hydraulic pressure indication will be normal (green) while the pump is running;
- however, the YELLOW system label and distribution triangle will be displayed in amber.
- This indicates that the yellow system is only partially powered.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
4. Electric Pump Indications
The triangle’s fill and color indicate the status of the pump:
- Open white triangle - The pump is not ________ to run.
- Solid green triangle - The pump is ________.
- Solid amber triangle - The pump is _____ but has ________ pressure.
- Open amber triangle - The pump is selected ________
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
4. Electric Pump Indications
The triangle’s fill and color indicate the status of the pump:
- Open white triangle - The pump is not commanded to run.
- Solid green triangle - The pump is ON.
- Solid amber triangle - The pump is ON but has low pressure.
- Open amber triangle - The pump is selected OFF.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
5. Engine Driven Pump Indications
- In-line green - The respective ENG 1(2) pb is on and hydraulic pressure is _______._
- Cross-line amber - The respective ENG 1(2) pb is ______.
- Amber LO - The respective ENG 1(2) pb is on and hydraulic pressure is ________.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
5. Engine Driven Pump Indications
- In-line green - The respective ENG 1(2) pb is on and hydraulic pressure is normal.
- Cross-line amber - The respective ENG 1(2) pb is OFF.
- Amber LO - The respective ENG 1(2) pb is on and hydraulic pressure is low.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
6. Fire Shutoff Valves
• In-line green - Fire shutoff valve is ________.
• Cross-line amber - Fire shutoff valve is fully ________.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
6. Fire Shutoff Valves
• In-line green - Fire shutoff valve is open.
• Cross-line amber - Fire shutoff valve is fully closed.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
7. Reservoir Indications
- The reservoir fill range is indicated in ________.
- The normal fill level is indicated by a ______ ______ that is corrected for changes in fluid _______._
- If temperature ________ is lost, the box changes to _______._
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
7. Reservoir Indications
- The reservoir fill range is indicated in white.
- The normal fill level is indicated by a green box that is corrected for changes in fluid temperature.
- If temperature correction is lost, the box changes to white.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
7. Reservoir Indications
The low fill level is indicated by an ______ ______.
If the fluid level falls to the low level:
- The fluid level ________ changes from green to amber.
- The reservoir ______ ______e changes from white to amber.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
7. Reservoir Indications
The low fill level is indicated by an amber box.
If the fluid level falls to the low level:
- The fluid level pointer changes from green to amber.
- The reservoir fill range changes from white to amber.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
7. Reservoir Indications
- The green fluid level indication and normal fill level increase slightly when the ______ ______ is ______.
- A white mark on the ________ system’s reservoir fill range indicates the ______ fill level for ______ ______ ______.
- If the fluid level is below the minimum fill level, the single white mark changes to ___ ______ marks.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
7. Reservoir Indications
- The green fluid level indication and normal fill level increase slightly when the landing gear is retracted.
- A white mark on the green system’s reservoir fill range indicates the minimum fill level for landing gear extension.
- If the fluid level is below the minimum fill level, the single white mark changes to two amber marks.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
8. OVHT
- OVHT is displayed in amber next to the affected reservoir if a reservoir ________ is detected.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
8. OVHT
- OVHT is displayed in amber next to the affected reservoir if a reservoir overheat is detected.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
9. LO AIR PRESS
- LO AIR PRESS is displayed in amber next to the affected reservoir if reservoir _______ air pressure is detected.
VOL. II, 29.3.2
HYD_02
Discuss normal and abnormal indications on the ECAM HYD page.
9. LO AIR PRESS
- LO AIR PRESS is displayed in amber next to the affected reservoir if reservoir low air pressure is detected.
VOL. II, 29.3.2