A room equipped with a shower or bathtub is a __
A. Toilet room
B. Bathroom
C. Shower room
D. Washroom
B. bathroom
Fixture connections that require the removal of an access panel for servicing are considered____
A. Accessible
B. Readily accessible
C. Not accessible
D. Exposed
A. Accessible
That part of the lowest piping of a drainage system that receives the discharge from soil, waste, and other drainage pipes inside the walls of the building and conveys it to a point 2 feet outside the building wall is a ___
A. Building drain
B. Building sewer
C. Waste pipe
D. Soil stack
A. building drain
A vertical vent that is a continuation of the drain to which it connects is a ___
A. Circuit vent
B. Relief vent
C. Continuous vent
D. Branch vent
C. continuous vent
A horizontal drain that is sized to provide free movement of air above the flow line of the drain is called a ____
A. Continuous waste system
B. Durham waste and vent system
C. Combination waste and vent system
D. Solvent waste and vent system
C. combination waste and vent system
The length along the centerline of the pipe and fittings is the ___
A. Diagonal length
B. Diameter length
C. Circumference length
D. Developed length
D. Developed length
A device integrated within an air accumulator vessel that is designed to discharge a predetermined quantity of water to fixtures for flushing purposes is a (an) _____
A. Expansion tank
B. Surge tank
C. Flushometer tank
D. Day tank
C. Flushometer tank
The combination of fittings that may be used to make an offset and is considered a vertical pipe are ___
A. 1-90 degree and 1-45 degree
B. 2-90 degree and 1-45 degree
C. 1-45 degree and 1-60 degree
D. 1-45 degree and 1-45 degree
D. 1-45 degree and 1-45 degree
Water that is satisfactory for drinking, culinary and domestic purposes and that meets the requirements of the Authority Having Jurisdiction is referred to by this code as ___
A. Potable water
B. Industrial water
C. Soft water
D. Hard water
A. Potable water
By code definition, a stack is always____
A. Straight
B. Horizontal
C. Vertical
D. Exposed
C. Vertical
A pipe that makes an angle of not more than 45 degrees with the cervical is considered ___
A. Vertical
B. Horizontal
C. Crooked pipe
D. Diagonal pipe
A. Vertical
The vertical depth of a trap seal is measured from ____
A. The crown weir to the top of the dip of the trap
B. The inlet of the trap to the bottom of the trap
C. The outlet of the trap to the bottom of the trap
D. The inlet of the trap to the outlet of the trap
A. The crown weir to the top of the dip of the trap
D. Trap arm
D. Private sewage + disposal system
B. Yoke vent
D. Sump
C. Indirect waste pipe
B. Grade of pipe
B. Critical level marking
A. Airgap
C. Horizontal branch
B. Wet vent
A mixing valve that senses outlet temperature and compensates for fluctuations in incoming hot or cold water temperature is a ____
A. Thermostatic (temperature control) valve
B. Combination thermostatic/pressure-balancing valve
C. Pressure-balancing valve
D. None of the above
A. Thermostatic (temperature control) valve
True or False:
The restroom facilities in a private day care center are classified as public use.
True
True or False:
The discharge from clinical sinks and conveyed to the building drain is defined as a waste pipe.
False
A combination building sewer is a ____
A. Combination of all sewer and drainage piping from inside and outside of a building
B. Building sewer that conveys industrial waste and domestic sewage
C. Building sewer that conveys both sewage and storm water
D. Building drains that convey waste and storm water
C. Building sewer that conveys both sewage and storm water