Cedo - (Section 7) Standard Operating Procedure Flashcards
0
Q
The source capsule assembly (pigtail) consist of what components?
A
- Connector
- Locking ball
- Source capsule
- Teleflex cable
1
Q
What is the main purpose of a “S” tube?
A
To prevent Gamma radiation from escaping from the exposure device.
2
Q
A legal requirement is that personal Dosimetry must be?
A
Worn at all times.
3
Q
Who may use an exposure device?
A
Only a Certified Exposure Device Operator or trainee under direct and continuous supervision.
4
Q
Any person who operates an exposure device shall?
A
- Wear a dosimeter that has issued by a licensed service.
- Has not been used by another person since last reading.
- Wear a second dosimeter that has a direct read display
- Able to record any dose
- Has been calibrated within 20 % accuracy in the last 12 months.
- Emits an audible warning when intensity reaches 5 mSv/hr or total absorbed dose reaches 2 mSv.
5
Q
every person who operated an exposure device shall?
A
- Use survey meter that is capable of measuring between 20 μSv and 100 mSv/hr.
- Indicates battery level.
6
Q
No licensee shall
A
Blah blah