What is the radiation storage area limit?
0.025 mSv/hr
What is the radiation barrier limit?
0.1 mSv/hr
What’s the radiation limit on the surface of a device?
2 mSv/hr
- Before use and upon installation of new source.
A working calibrated survey meter must be capable of measuring in what range?
Between 20μSv to 100 mSv/hr
Survey meters must be calibrated once every?
12 months.
If a DRD reading exceeds 2 mSv during a shift, what should be done?
Stop work and investigate?
When must a leak test be performed?
Once a year or upon new source installation.
If a reading of 200 Bq or higher is obtained withdraw from use.
Long-handled tongs must be a minimum of what length?
1.5m
Collimators must have a minimum shielding factor of?
100 SF
Audible dosimeters must be calibrated how often?
12 months
Audible dosimeters must alarm when intensity reaches a momentary dose of what? And a total absorbed dose of?
- 5 mSv/hr momentary
- 2 mSv total absorbed dose