CBS Flashcards

1
Q

State Pressure limit for Containment

A

52#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

State when CBS pumps start on LOP

A

either at SR3

Or at HR8, there is a 5 sec delay if that train of CT pump just started for Starting amps to decay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State when CBS-V-8/14 get auto open signal

A

120,478 Gal in RWST, 2/4 logic
Interlocked with RHR loops isolation valves
Requires operator to close CBS-V-2/5 within 3 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

State T.S. limits on RWST

A

477,00 gallons
min temp 50F
max temp 98F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

State worse case scenario for LOCA and why

A

RCS crossover leg.

  • High venting rate (pipe is larger)
  • path of least resistance
  • after partial blowdown S/G’s become a heat source
  • peak pressure 49.6#
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State two reasons why Iodine is kept in solution

A

Iodine in gaseous form leaks out of containment

Iodine is absorbed into the thyroid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

State why we use NaOH in the SAT

A

Raises pH to 8.5 - 11

Chemical reaction keeps Iodine in solution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

State setpoints and coincidences of CSAS

A

Manual, 2/2, also causes CVI and Phase B

HI-3, 18#, 2/4, also Phase B isolation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Explain the limits on pH for CBS

A

Lower limit to keep iodine in solution

Upper limit is to prevent stress corrosion cracking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

State T.S. 3.5.4 (RWST) LCO and Actions

A
The RWST shall be operable with:
477,000 gallons
Concentration listed in COLR
min temp 50F
max temp 98F

If LCO can not be met the restore to OPERABLE within 1 hour or be in HOT STANDBY within 6 hrs and COLD SHUTDOWN within the following 30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

State plant response to a CSAS

A

CBS pumps start
CBS-V-11/17 open (Containment isolations)
CBS-V-30,31 and 33 close (recirc isolations)
CBS-V-38,43 open (SAT isolations)
Phase B isolation
Manual initiates CVI (normally done by S-signal)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

State plant response to a P signal

A

CRDM fans trip
CC-V-137 & 266, CBS HX PCCW outlets, open
CAH-FN-3-A & B, cont recirc fans, start in the RECIRC mode
PCCW containment isolations close
Requires RCP trip due to loss of cooling (loss of forced cooling)
Containment cooling fans will also trip on low CC flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Discuss auto swap over to containment sumps

A
Opening CBS-V-8 and 14
‘S’ signal lock in
coincident with RWST lo-lo level (2/4 @ 120,478 gal) 
Closing CBS-V-2 and 5
Manually closed by procedure (ES-1.3)
Time limit for switchover is 180 seconds
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

State T.S. 3.6.1.1 for Containment Integrity LCO and Action

A

Primary CONTAINMENT INTEGRITY shall be maintained.
MODES: 1,2,3, and 4
Without primary CONTAINMENT INTEGRITY, restore CONTAINMENT INTEGRITY within 1 hr or be in atleast HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

State T.S. 3.6.1.2 For Containment Leakage LCO and Action

A

Leakage rates shall be limited in accordance with the LLRT program
MODES: 1,2,3, and 4
With the overall integrated leakage rate exceeding 1.0 La restore CONTAINMENT INTEGRITY within 1 hr or be in atleast HOT STANDBY within the next 6 hrs and in COLD SHUTDOWN within the following 30 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

State T.S. for Internal Pressure LCO and Action

A

Primary containment internal pressure shall be maintained between 14.6 and 16.2 psia
MODES: 1,2,3, and 4
With the containment internal pressure outside of the limits above, restore the internal pressure to within the limits within 1 hour or b in at least HOT STANDBY within the next 6 hrs and in COLD SHUTDOWN within the following 30 hrs.