State Pressure limit for Containment
52#
State when CBS pumps start on LOP
either at SR3
Or at HR8, there is a 5 sec delay if that train of CT pump just started for Starting amps to decay
State when CBS-V-8/14 get auto open signal
120,478 Gal in RWST, 2/4 logic
Interlocked with RHR loops isolation valves
Requires operator to close CBS-V-2/5 within 3 min
State T.S. limits on RWST
477,00 gallons
min temp 50F
max temp 98F
State worse case scenario for LOCA and why
RCS crossover leg.
- High venting rate (pipe is larger)
- path of least resistance
- after partial blowdown S/G’s become a heat source
- peak pressure 49.6#
State two reasons why Iodine is kept in solution
Iodine in gaseous form leaks out of containment
Iodine is absorbed into the thyroid
State why we use NaOH in the SAT
Raises pH to 8.5 - 11
Chemical reaction keeps Iodine in solution
State setpoints and coincidences of CSAS
Manual, 2/2, also causes CVI and Phase B
HI-3, 18#, 2/4, also Phase B isolation
Explain the limits on pH for CBS
Lower limit to keep iodine in solution
Upper limit is to prevent stress corrosion cracking
State T.S. 3.5.4 (RWST) LCO and Actions
The RWST shall be operable with: 477,000 gallons Concentration listed in COLR min temp 50F max temp 98F
If LCO can not be met the restore to OPERABLE within 1 hour or be in HOT STANDBY within 6 hrs and COLD SHUTDOWN within the following 30
State plant response to a CSAS
CBS pumps start
CBS-V-11/17 open (Containment isolations)
CBS-V-30,31 and 33 close (recirc isolations)
CBS-V-38,43 open (SAT isolations)
Phase B isolation
Manual initiates CVI (normally done by S-signal)
State plant response to a P signal
CRDM fans trip
CC-V-137 & 266, CBS HX PCCW outlets, open
CAH-FN-3-A & B, cont recirc fans, start in the RECIRC mode
PCCW containment isolations close
Requires RCP trip due to loss of cooling (loss of forced cooling)
Containment cooling fans will also trip on low CC flow
Discuss auto swap over to containment sumps
Opening CBS-V-8 and 14 ‘S’ signal lock in coincident with RWST lo-lo level (2/4 @ 120,478 gal) Closing CBS-V-2 and 5 Manually closed by procedure (ES-1.3) Time limit for switchover is 180 seconds
State T.S. 3.6.1.1 for Containment Integrity LCO and Action
Primary CONTAINMENT INTEGRITY shall be maintained.
MODES: 1,2,3, and 4
Without primary CONTAINMENT INTEGRITY, restore CONTAINMENT INTEGRITY within 1 hr or be in atleast HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.
State T.S. 3.6.1.2 For Containment Leakage LCO and Action
Leakage rates shall be limited in accordance with the LLRT program
MODES: 1,2,3, and 4
With the overall integrated leakage rate exceeding 1.0 La restore CONTAINMENT INTEGRITY within 1 hr or be in atleast HOT STANDBY within the next 6 hrs and in COLD SHUTDOWN within the following 30 hours