C5 Dash 8 Caution and Warning Flashcards
TOUCHED RUNWAY
Fuselage contact with runway - Series 300
1 ENG OIL PRESS
Low Oil Pressure #1 Engine
2 ENG OIL PRESS
Low Oil Pressure #2 Engine
SMOKE
Smoke Present in Baggage Area
CHECK FIRE DET
Engine Fire Detected or Detector Loop Malfunction
CABIN PRESS
Cabin Altitude Exceeds 10,000 Feet
PASS DOOR
Passenger Entry Door not Properly Secured
BAG DOOR
Baggage Door Not Properly Closed
SERV DOOR
Rear Galley Service Door not Properly Closed (-300)
FWD EXIT DOOR
Forward Exit Door not Properly Closed (-300)
MAIN BATT HOT
Main Battery Temperature Exceeds 65C
AUX BATT HOT
Auxiliary Battery Temperature Exceeds 65C
FLT COMPT DUCT HOT
Overheat Condition in Flt Compt A/C Supply Duct
- 200: System will automatically respond by closing Flight Compartment Trim Valves
- 300: System will automatically respond by closing #2 Fwd Pack Valves.
When duct temperature returns to its normal range the caution light will extinguish and system will resume normal operation.
CABIN DUCT HOT
Overheat Condition in Cabin A/C Supply Duct
- 200: System will automatically respond by closing pack valves closed on the ACM.
- 300: System will automatically respond by closing pack valves on #1 ACM.
When duct temperature returns to normal operating range the caution light extinguishes and A/C system resumes normal operation.
AIR COND PACK HOT
Overheat Condition in Air Cycle Machine (-200)
System will shut HPSOV and NSOV for both engines.
When temperature returns to normal range the caution light will extinguish and bleed airflow will be restored.
FLT COMPT PACK HOT
Overheat Condition in the #2 Forward ACM (-300)
PRSOV for Pack #2 will close.
PRSOV will open and caution light will extinguish when temperature returns to normal range.
CABIN PACK HOT
Overheat Condition in the #1 Aft ACM (-300)
PRSOV for Pack #1 will close.
PRSOV will open and caution light will extinguish when temperature returns to normal range.
APU
Fault and automatic shutdown of APU.
Reference APU Control Panel for specific APU condition.
PRI INV
Primary Inverter Inoperative
SEC INV
Secondary Inverter Inoperative
L TRU
Left TRU Inoperative
DC Logic System will close Secondary Bus Tie to power Left Secondary Bus
R TRU
Right TRU Inoperative
DC Logic System will close Secondary Bus Tie to power Right Secondary Bus
MAIN BATTERY
Main Battery is Isolated from the Main DC Bus
AUX BATTERY
Aux Battery is Isolated from the Main Bus
1 DC GEN
1 DC Generator Failed or Offline
DC Logic system has taken Gen offline via its GCU and has closed Main Bus Tie to power Left Main Bus
2 DC GEN
2 DC Generator Failed or Offline
DC Logic system has taken Gen offline via its GCU and has closed Main Bus Tie to power Right Main Bus
1 AC GEN
1 AC Generator Failed or Offline
AC Gen GCU circuits will close AC Cross Tie.
2 AC GEN
2 AC Generator Failed or Offline
AC Gen GCU circuits will close AC Cross Tie.
AUX INV
Secondary Inverter Inoperative
L 26 AC
Left 26v Transformer Inoperative
R 26 V
Right 26v Transformer Inoperative
L AC BUS
No Power on Left Variable Frequency Bus
GCU Logic circuits will isolate AC Generator from faulty bus. DC Logic Circuits will close Secondary DC Bus Tie to let Right TRU power both Secondary Buses.
All services normally supplied by faulty bus will be lost.
R AC BUS
No Power on Right Variable Frequency Bus
GCU Logic circuits will isolate AC Generator from faulty bus. DC Logic Circuits will close Secondary DC Bus Tie to let Left TRU power both Secondary Buses.
All services normally supplied by faulty bus will be lost.
DC BUS
DC Bus Fault Detected
BBPU has inhibited closing of Main and Main/Secondary Bus Ties
L TRU HOT
Left Transformer Rectifier Unit Overheated
R TRU HOT
Right Transformer Rectifier Unit Overheated
1 DC GEN HOT
1 DC Generator Windings Overheated
2 DC GEN HOT
2 DC Generator Windings Overheated
1 AC GEN HOT
1 AC Generator Windings Overheated
2 AC GEN HOT
2 AC Generator Windings Overheated
EMER LTS DISARMED
Emergency Lights not Armed with DC System Energized
RUD PRESS
Failure of Rudder Pressure to Decrease when IAS > 140/150
Will also illuminate with one Rudder Actuator Failed as Functioning Actuator will have full 3,000 psi.
ROLL SPLR INBD HYD
Inboard Spoiler Extend Circuit Depressurized
ROLL SPLR OUTBD HYD
Outboard Spoiler Extend Circuit Depressurized
1 RUD HYD
1 Rudder Actuator Depressurized
Rudder Pressure Regulator will admit full hydraulic pressure (3,000 psi) to #2 Rudder Actuator
2 RUD HYD
2 Rudder Actuator Depressurized
Rudder Pressure Regular will admit full hydraulic pressure (3,000 psi) to #1 Rudder Actuator
RUD FULL PRESS
One Rudder Actuator has Full Hydraulic Pressure (3000 psi)
FLAP DRIVE
Main Flap Drive Failed
Secondary Shaft will continue to provide normal operation
FLAP POWER
Loss of pressure to Flap Power Unit (less than 1,500 psi)
FLT DATA RECORDER
Recorder Failed or De-engergized
Can be malfunction or A/COL (beacon) being selected off.
1 ENG FUEL PRESS
1 Boost Ejector Pump Failed
Fuel pressure of fuel being delivered to left engine driven fuel pump is low.
2 ENG FUEL PRESS
2 Boost Ejector Pump Failed
Fuel pressure of fuel being delivered to right engine driven fuel pump is low.
1 TANK FUEL LOW
1 Tank Quantity Less than 130 Pounds
Equals approx 12 minutes of operating time on associated engine unless fuel is transferred.
2 TANK FUEL LOW
2 Tank Quantity Less than 130 Pounds
Equals approx 12 minutes of operating time on associated engine unless fuel is transferred.
FUELING ON
Refuel or Defuel Selected on Fueling Control Panel
Aircraft would be unable to crossfeed in flight.
1 FUEL FLTR BYPASS
1 Fuel Filter Blocked or Restricted
Fuel system will automatically reroute fuel around affected filter.
2 FUEL FLTR BYPASS
2 Fuel Filter Blocked or Restricted
Fuel system will automatically reroute fuel around affected filter.
1 HYD FLUID HOT
Overtemp Condition in #1 Hydraulic Reservoir
2 HYD FLUID HOT
Overtemp Condition in #2 Hydraulic Reservoir
1 STB HYD PUMP HOT
Overtemp Condition in #1 Standby Pump Windings
2 STB HYD PUMP HOT
Overtemp Condition in #2 Standby Pump Windings
2 SPU AUX PWR
2 Standby Hydraulic Pump Powered by #2 AC Generator
Switches automatically from #1 AC Bus if #1 AC Bus goes offline.
1 ENG HYD PUMP
Low Pressure from the #1 Main Hydraulic Pump
The #1 Standby Hydraulic Pump can be selected on to restore hydraulic pressure to the #1 system.
2 ENG HYD PUMP
2 Standby Hydraulic Pump will be activated automatically from a low pressure switch.
Low Pressure from the #2 Main Hydraulic Pump
PITOT HEAT 1
1 Pitot Heater Off
PITOT HEAT 2
2 Pitot Heater Off
L ELEV HORN HEAT
Left Elevator Horn Heat Failure
Also illuminates during Elevator Horn Heat test.
R ELEV HORN HEAT
Right Elevator Horn Heat Failure
Also illuminates during Elevator Horn Heat test.
L WSHLD HOT
Left Windshield Overheated
System will de energize window until the window temperature cools.
Or loss of power to window heater element.
R WSHLD HOT
Right Windshield Overheated
System will de energize window until the window temperature cools.
Or loss of power to window heater element.
SIDE WDO HOT
Pilot’s Side Window Overheated
System will de energize window until the window temperature cools.
Or loss of power to window heater element.
DEICE PRESS
Deice Pressure Too Low for Boot Operation
NOSE STEERING
Steering ECU Malfunction
Exceeding 60 deg of travel in free castor mode.
Light will extinguish when nosewheel is back within 60 deg of center.
PARKING BRAKE
Parking Brake in On
OUTBD ANTI SKID
Outboard Anti-Skid Control Unit Failure
Also illuminates during self-test.
INBD ANTI SKID
Inboard Anti-Skid Control Unit Failure
Also illuminates during self-test.
LND GEAR INOP
Failure of Landing Gear Door Sequencing Valve
WT ON WHEELS
Fault in Weight on Wheels Sensing Circuits
1 BLEED HOT
Overheat Condition in #1 Bleed Air Supply Duct
HPSOV and NSOV will close on affected side until bleed system returns to normal temperature.
2 BLEED HOT
Overheat Condition in #2 Bleed Air Supply Duct
HPSOV and NSOV will close on affected side until bleed system returns to normal temperature.
1 ENG MANUAL
Failure of #1 Engine ECU
- Fuel scheduling will revert to manual via MFC
- Torque increase of 8-10%
- Loss of Np Underspeed Protection
- Loss of HBOV automatic operation
- Loss of power uptrim
2 ENG MANUAL
Failure of #2 Engine ECU
Fuel scheduleing will revert to manual via MFC Torque increase of 8-10% Loss of Np Underspeed Protection Loss of HBOV automatic operation Loss of power uptrim
L STALL WARNING
Left Lift Computer or Lift Transducer Inoperative (-200)
Also loss of heater element in associated transducer.
Fast-slow indicator on left EADI will be inoperative.
R STALL WARNING
Right Lift Computer or Lift Transducer Inoperative (-200)
Also loss of heater element in associated transducer.
Fast-slow indicator on right EADI will be inoperative.
1 STALL SYST FAIL
Fault in #1 Stall Warning / Stick Pusher Computer (-300)
Also #1 AOA heater element failure or #1 AOA vane power loss.
PUSHER SYS FAIL caution will illuminate as well.
2 STALL SYST FAIL
Fault in #2 Stall Warning / Stick Pusher Computer (-300)
Also #2 AOA heater element failure or #2 AOA vane power loss.
PUSHER SYS FAIL caution will illuminate as well.
PUSHER SYST FAIL
Malfunction in Stick Pusher System (-300)
Stick pusher will be offline
GPWS
Failure of Ground Proximity Warning System