Building Construction Flashcards

1
Q

List 6 hazards of sandwich panels

A

Toxic smoke

Hard to extinguish due to outer layer protecting inner

Rapid fire spread

Falling outer panels

Can look after than they are

Can fail at any time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Timber starts charring at _____ *C

Timber has a ______ _______ to protect the inside.

A

350*C

Sacrificial layer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Steel loses ___ of its strength at _____ *C

A

2/3

600*C

How well did you know this?