Breathing Apparatus Flashcards
Respiratory Hazards at a fire
High temp, Oxygen deficency, Toxic Atmosphere, Smoke inhalation
Working time in BA
2040L/60LPM= 34 min
- 10 min for decon
= 24 mins working time.
Change of shift check
- Visual inspection, Battery level, Control module self-check, Pressure seal test, Motion alarm and manual distress alarm, Depressurize and check mechanical whistle and low-pressure alarms, Voice projection speaker.
Difference between stage 1 and Stage 2 BA
Stage 1 6 tally tags
Stage 2 12 tally tags
Stage two is implemeted when a higher level of control is needed.
What to do if set is faulty
- Write down error code
- disconnect battery and retest set.
- Write down error code.
- Notify oic and fill out form
- send to BA station 38
Name the 8 Components of the BA set
Cylinder, Face mask, Demand Valve, Pressure Reducing vale, Carrier Frame and harness, Mechanical Whistle, Buddy Breather, Control module
Define Primary Search
Rapid but throughour search of all compartments that are safe to enter, its purpose is to find and remove all occupants. Emphasis on speed but not at the expense of throughorness
Define Secondary search
Once the situation is under control, a secondary search is a throughough search to account for all occupants and determine casualties.
List the priorities in search and rescue
1.Rescue the most threatened
2. Rescue the largest group
3. Rescue remaining occupants in the building
4. Rescue anyone in exposed areas