Bleed Air System Flashcards
1
Q
BLEED TRIP LIGHT
A
-at a temperature of 490degrees
And/or
- at a pressure of 220psi
The bleed air valve closes
2
Q
DUAL BLEED LIGHT
A
Will illuminate when
1) APU bleed air valve is open and the number 1 engine BLEED air switch is ON
2) APU bleed air valve is open, the number 2 engine BLEED air switch is ON and the isolation valve is open
3
Q
APU Bleed air can be used
Altitude
A
17000’
4
Q
Which side of the pneumatic manifold normally receives external ground air?
A
Right
5
Q
With the ISOLATION VALVE switch selected to AUTO, the valve will open when:
A
Either PACK switch is selected OFF, or either engine BLEED Air switch is selected OFF
6
Q
WING BODY OVERHEAT
A
There is a bleed air leak in one of the 8 sensor zones