BC Quiz 2 Flashcards
01. Which Engine must ensure a hose line is stretched to feed the sprinkler system siamese at a taxpayer cockloft fire? Select one: a. First Engine b. Fourth Engine c. Third Engine d. Second Engine
(TP 7.3.5 B)
The correct answer is: Third Engine
- The second engine may stretch a backup line, at a taxpayer cellar fire with a sprinkler system, if staffing and conditions permit?
Select one:
a. Only if the backup line is urgently needed. In this case, the 3rd engine would then ensure the sprinkler is supplied.
b. Only after they have supplied the sprinkler system
(TP 7.2.3 B)
The correct answer is: Only after they have supplied the sprinkler system
- At a taxpayer store fire during business hours, the first hose line should be stretched?
Select one:
a. Through broken store front windows
b. Through the store entry / exit door
(TP 7.3.1A)
The correct answer is: Through broken store front windows
- At a taxpayer store fire during business hours, the second hose line should be stretched?
Select one:
a. To the store on fire with the first line
b. To the most severely exposed store
(TP 7.3.1 B)
The correct answer is: To the store on fire with the first line
05. At taxpayer cockloft fires, the IC \_\_\_\_\_\_ order a handline with a cockloft nozzle into the interior to knockdown the fire in the cockloft? Select one: a. Should not b. Shall c. May, only if absolutely necessary d. May, if necessary
(TP 7.3.3 B)
The correct answer is: Shall
- The last resort at taxpayer cockloft fires is?
Select one:
a. Cutting a trench
b. Use of cellar pipes, distributors or the NY bent tip from the roof
c. Operating hose lines directly into roof openings
d. Use of a tower ladder pipe, multiversal and deckpipe streams
Feedback
(TP 7.3.3 D, F, I)
The correct answer is: Use of a tower ladder pipe, multiversal and deckpipe streams
- The second engine may stretch a backup line, at a taxpayer store fire with a sprinkler system, if staffing and conditions permit?
Select one:
a. Only after they have supplied the sprinkler system
b. Only if the backup line is urgently needed. In this case, the 3rd engine would then ensure the sprinkler is supplied.
(TP 7.3.5 A)
The correct answer is: Only after they have supplied the sprinkler system
- E-99 arrives first at a taxpayer cockloft fire in a pizzeria that has control of the cockloft, is blowing through the roof and seriously threatening to extend to an H-type building. Which action(s) below were they correct to take?
Select one or more:
a. Stretch the first line into the pizzeria to knock down the main body of fire
b. Utilize In-Line Pumping to position their deckpipe
c. Position the engine for use of their deckpipe
d. Stretch the first line into the H-type
(TP 7.3.5 B)
The correct answers are: Stretch the first line into the H-type, Position the engine for use of their deckpipe, Utilize In-Line Pumping to position their deckpipe
- E-98 arrives second at a taxpayer cockloft fire in a pizzeria that has control of the cockloft, is blowing through the roof and seriously threatening to extend to an H-type building. They would be correct to first?
Select one:
a. Assist the first Engine with the initial line
b. Immediately stretch a second line if staffing and conditions permit
(TP 7.3.5 B)
The correct answer is: Assist the first Engine with the initial line
- Tower Ladders should be positioned in front of taxpayers in preference to conventional aerial ladder apparatus.
Select one:
a. Agree
b. Disagree
(TP 8.1.19)
The correct answer is: Agree
- At taxpayer cellar fires, it would be incorrect to state?
Select one:
a. When cutting the first floor for a cellar fire, do not cut until a hose line is in position
b. If smoke shows in many stores and there is high heat conditions on the first floor with no visible flame, suspect a cellar fire
c. Smoke ejectors can be placed over holes cut in floors
d. When cutting the first floor for a cellar fire, always open up directly over the main area of involvement
(TP 8.2.1 B, H, I ,K) Incorrect Choice - When cutting the first floor for a cellar fire, opening up directly over the main area of involvement may not always be practical
The correct answer is: When cutting the first floor for a cellar fire, always open up directly over the main area of involvement
12. At which fires must ventilation of the taxpayer store by removal of show windows be done only when ordered by the IC and only when a charged line is in position? Select one: a. Both cellar and store fires b. Store fires only c. Cellar fires only
(TP 8.2.2 A, 8.3.1 E, 8.3.3 A3)
The correct answer is: Store fires only
13. The first and second roof firefighters should each place a portable ladder to the roof of a 1-story taxpayer, and they should both bring a portable saw to the roof at \_\_\_\_\_\_\_\_\_\_? Select one or more: a. Cockloft fires b. Cellar fires c. Store fires
(TP 8.2.2 A2, B2—8.3.3 A2, B2) (Only the second roof FF brings saw at cellar fire)
The correct answers are: Store fires, Cockloft fires
- The second tower ladder to arrive at a fire in a taxpayer that faces two streets should place their Tower Ladder considering which thought?
Select one:
a. The first consideration is to insure the entire front of the building is covered by Tower Ladders before covering the other street front
b. The first consideration is the uncovered street
Feedback
(
(TP 8.2.2 A4, 8.3.2 A4)
The correct answer is: The first consideration is to insure the entire front of the building is covered by Tower Ladders before covering the other street front
- The practicality of trenching a taxpayer roof depends on which factors? (More than one correct)
Select one or more:
a. Volume of fire
b. Ceiling type
c. Ceiling height
d. Size of the roof
(TP 8.3.2 D)
The correct answers are: Size of the roof, Volume of fire, Ceiling height, Ceiling type