B747-400 Sys Switch AQP sit Flashcards
power up check establish power check
Batt switch off what busses do you have?
Off-2 busses main hot battery and apu hot battery bus.
Batt swt on what buses do you have?
4 total. Main hot battery bus, apu hot battery bus, main battery bus, apu battery bus.
Duration of fully charged battery?
30 min.
Standby power selector to auto what items do you have.
Pfd,nd,L fmc, L cdu, primary eicas,L adc, L eiu, L efics panel, stand by instruments.
What is power source for main and apu standby power.
Main powered by ac bus 3, apu standby powered by capt transfer bus.
Secondary power with loss of ac bus 1&3,
Main and apu hot battery bus via inverters.
Why do 2 flap indicators show flaps extended and 2 do not?
When battery switch on and the standby power switchis inauto and no other power is on the airplane, the standby power system excitation to the right wing but not the left wing.
What does x represent ?
Invalaid data
Note do not move flaps handle to match flaps.
Hydalic demand pumps off why is it important to have demand pumps off?
What if #2 selector is in auto would it be running now?
No, 1&4 are air driven
What if selector #4 is in auto, would it be running now?
No, 2&3 elect driven.
Why is it important for wipers to be off?
So you dont damage screen.
What position should the flaps handle be in.
Both position and handle should agree, leave in up position.
Alt flap selector off, what would happen if switch was in the alt position?
Arms alt flaps knob, shuts off primary and secondary modes, asymmetry not available and flap lever inop.
If the alt flap selector was in EXt , would flaps be extending?
Leading edge and trailing edge EXt elect. Max range 25 degrees.