What should be done if a missing street sign poses an exceptional problem for apparatus response?
A report noting the condition sent to Assistant Chief of design and construction copy and forward to bureau of operations
SPEED HUMPS or “vertical traffic calming device”, “pavement undulation”, or “sleeping policeman” are?
3-4” raised, slightly longer than avg auto and span the width of the street. When sign for speed humps missing, report shall be forwarded to bureau of operations.
Advisory speeds= 15 MPH for 4”
20 MPH for 3”
Speeds shall be adhered to at ALL times
Speed BUMPS are 3-6” high and 12” wide and are illegal in NYC
What form must SA officers fill out and forward to assigned Div each tour?
BP-82
Buckeye pipeline consists of….?
(2) 12” steel pipes
(1) gasoline (1) kerosene bases aviation fuel
Operates at 1,200 psig in Linden NJ
Max service pressure on terminal pipping and delivery to shippers line in LIC is 200 psig.
Control valves in Buckeye pipeline automatically limit pressure in main line to..?
1200 psig.
- pressure switches shut down pump if control valves fail
- Relief valves kick in in both fail
- Automatic valves normally require no FD action
Types of wrenches for Buckeye Pipeline?
(1) Short “T”, which is used to open hinged cover of valve
(2) 3 1/3’ YELLOW wrench with FEMALE fitting
(3) Combo wrench, also 3 1/2’ and YELLOW with fitting for opening cover on one end of “T” handle
How is manual shut off to Buckeye pipeline accomplished?
Shut off generally located below ground under hinged cover.
1/4 turn left or right to open cover
-3 1/2’ wrench with female coupling inserted and turned 42 FULL turns or 84 Half turns CLOCKWISE
-EXCEPTION are valves at SHIPPERS LINE LIC, these require 24 FULL or 48 HALF CLOCKWISE turns
-Above ground valves are located behind metal wire fence
-Div 8 has Buckeye Pipeline Coordinator.
Normally assigned units to Buckeye pipeline shall carry how many wrenches?
(1) set on rig and (1) permanently marked at H.W. with Alarm assignment cards and extra pipeline map.
- Additional foam shall be stored with spare wrenches
- Additional Engines responding from qtrs on 2nd alarm associated with leak shall place additional foam on apparatus
- If 10-8 when ticket received MUST NOT return to qtrs
When operating at verified leak (2nd Alarm), units assigned to closing a valve and patrolling to adjacent valve….?
Both functions will be carried out simultaneously
- foot patrols carried out by (2) HT equipped members
- If ignition occurs prior to FD arrival, ISOLATION of pipeline by closing valves is still of primary importance.
- closed valves ONLY opened by Buckeye personnel when directed to do so by IC
What is PRIMARY consideration at leak from Buckeye pipeline?
EVACUATION of area involved
-Avenues of Escape MUST remain open
-If strong wind blowing all ignition sources in the path of drifting vapors must be extinguished and then all ignition sources in the area
What type of day presents the greatest potential for explosion?
Hot, humid, calm day
Rig distance from leak at Buckeye pipeline?
Not closer than 600’
How to create a path for rescue at Buckeye pipeline fire?
SOLID hose stream held HORIZONTAL a few inches above the ground moved rapidly side to side will create a path for rescue
How far must flag persons be placed at a buckeye pipeline incident near a railroad?
1000’ on each side of incident
When are Buckeye pipeline valves inspected?
Inspect during hydrants and familiarization drills
- If critical need for repair noticed immediately contact Div 8 coordinator
- BOROUGH Drills (in Oct/Nov) ONLY drill when valves ARE shut
What is Iroquis Pipeline?
Single 24” high strength steel pipeline that interconnects w/ConEd, carrying Natural Gas under pressure.
Max operating pressure of 1,440 psig
Typical operating range between 400-1,100 psig
How many turns to shut off valve in hunts point (Iriquios pipeline) which is covered by flush mount valve box similar to Con Ed manhole cover?
213 Full turns
Special wrench stored inside entrance gate
Another at FDNY command post at 500 Food Center Drive
And R-3 carries a hydraulic wrench
When should Iriquois pipeline valve be shut?
Except when immediate threat to life or property, no valves should be opened or closed without approval of FD IC in consult with Con Ed
INITIAL action at Iriquios pipeline are?
Set perimeter and Eliminate ignition sources
If ignited consider shutting gas supply
What is PRIMARY consideration at Iriqouis pipeline?
Evacuation of Area involved
Avenues of escape MUST remain open for civilians and PD
Iriquois pipeline, how far for flag persons?
At least 1000’ on each side of leak, HT and flashlight equipped
When can Iriquios pipeline valves be operated for drill
Under NO circumstance shall valves be operated w/o consult of ConEd and Iriquios
-NEVER FULL closure during drills
Who shall perform patrol of pipeline to locate leak at Iriquios pipeline?
Squad or SSL
When are brush fires most common?
Spring and Fall