Attic Insulation Flashcards

1
Q

What is the minimum acceptable clearance between a heat-producing device (HPD) and the surrounding insulation?

A

3 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many inches must the barrier around a heat-producing device (HPD) extend above the top of the loose fill insulation?

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How much clearance must be kept around (a) the back/sides and (b) front of an FAU located in an attic?

A

(a) 12”

(b) 24”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Use at least one insulation ruler for every ___ sq ft of attic space.

A

250

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does NFVA mean?

A

Net Free Venting Area: the total area of a vent minus mesh screening and louvers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What type of recessed light fixture can be buried under insulation?

A

IC-rated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What distinguishes an ICAT from an IC recessed light fixture?

A

Both are rated for insulation contact; however, ICAT (Insulation Contact Air Tight) fixtures do not require additional air sealing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What documentation needs to accompany the installation of a measure not addressed in the Specifications to gain inspector approval?

A

Product specification sheet (cut sheet) from the manufacturer and photo(s) of installed measure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

To the nearest inch, what is the minimum level of loose fill (a) cellulose and (b) fiberglass needed to achieve R38?

A

(a) 11”

(b) 14”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

List three common presumed asbestos-containing materials (PACM) in attics that should only be removed by a certified abatement specialist.

A

Transite
Vermiculite
Old duct tape/insulation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

As a best practice, what can be done to prevent the migration of dust through the attic hatch into the home during the attic insulation process?

A

Positively pressurize the living space (using a blower door or duct blaster)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

As a best practice, what material, rated at R7 per inch, could be used to achieve maximum R-value in a confined space such as beneath a furnace platform?

A

Polyisocyanate rigid board

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What type of attic insulation should be treated as a presumed asbestos-containing material (PACM)?

A

Vermiculite

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

As a best practice, what type of fixture should all recessed light fixtures be replaced with to minimize fire risks and simplify the insulation process?

A

ICAT-rated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly