The streak artifact in this case is caused by the arms of the patient being in above the head position and outside the scan FOV.

When anatomy or anything else somewhat dense (IV bags, monitoring equipment) is outside the scan FOV, it will only be seen by the scanner on some projections (incomplete projection artifact) and cause errors in the reconstruction, resulting in streaking. The geometry of the streak artifact converges outside the FOV and not at the calvarium and thus cannot be beam hardening artifact, which would be more pronounced at lower kVp settings.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
A

beam hardening due to contrast

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
A

cupping artifact on left, post correct on right.

X rays passing through the middle portion of a uniform cylindrical phantom are hardened more than those passing though the edges because they are passing though more material. As the beam becomes harder, the rate at which it is attenuated decreases, so the beam is more intense when it reaches the detectors than would be expected if it had not been hardened. Therefore, the resultant attenuation profile differs from the ideal profile that would be obtained without beam hardening (Fig 2). A profile of the CT numbers across the phantom displays a characteristic cupped shape

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

how do you fix beam hardening?

A
  1. filtration - pre hardening of the beam to remove lower E components before it hits the patient, and/or the addition of a bowtie filter
  2. calibration correction - using a phantom to allow the detector to compensate for hardening artifacts
  3. correct software - an interative algorith can be used
  4. avoidance - tilt the gantry or position th epatien tto avoid areas that cause hardening
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

To limit image noise, ______________ can be generated by adding together several thin sections.

A

To limit image noise, thicker sections can be generated by adding together several thin sections.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
A

partial volume artifact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

how do you decrease windmill artifact?

A

thicker slices

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
A

metal artifact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

CT tech calls you to the scanner to console a pt who the tech just told has a horrible liver cancer. What is your next step?

A

get delayed images (10-20 min). this is most likely a cavernous hemangioma

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

You think that the following is a hemangioma in a fatty liver, but the mid-level provider doesn’t believe you. The patient has abandoned pacer leads and can’t get an MRI. What is your next step?

A

Tagged RBC scan to look for hemangiomas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
A

tagged RBC scan demonstrating hemangiomas in the liver

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
A

FNH

hot on sulfur colloid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

retains eovist on delayed MR scan

A

FNH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly