APU - Auxilary Power Unit Flashcards

1
Q

Type

A

Honeywell(Garret) GTCP 36-150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

MAX RPM

A

107%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

MAX EGT

A

743C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

START 1 and 2 - Battery

A

Start 1 - 30 seconds
Start 2 - 30 seconds
–followed by 20min off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Start 1 and 2 - Ground Power

A

Start 1 - 15 Seconds
Start 2 - 15 Seconds
–followed 20 min off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Delay between cranking

A

A two minute delay should be observed between cranking attempts to allow for cooling of starter and start contactor and for APU drainage.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

APU Bleed Air - Air conditioning

A

Bleed Air not permitted above 15,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

APU Bleed Air - Enine start during ground operations

A

No Bleed Air extraction limitation. Each engine may be started using the APU bleed Air, then the operating engines thrust must not exceed 70% N2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Engine start during flight

A

During single engine operations, APU bleed Air extraction for an engine start is not permitted.

During double engine failure conditions, APU bleed Air extraction for engine starts is permitted. However, APU bleed Air extraction is 13,000ft and below.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly