Allied Signal RE 220
APU max Operating Altitude (ft)
41.000
Max Alt APU Bleed Air
—> Packs (ACUs) (ft)
25.000
Max Alt APU Bleed Air
—> Engine Start (ft)
25.000
APU Gen Max Load (kVA)
40
APU max RPM (%)
106
APU max continuous
On ground
682 - 789
EGT
In-flight
773 - 806
APU max EGT
1.038
OVSPD
auto shutdown in-flight & on ground
true or false?
true
OVTP
auto shutdown at touch-down
+ how many seconds?
60
Min OAT for cold soaked APU
start on ground (degrees Celsius)
-40
APU starter motor duty cycle
max starts / start attempts / hr
3
Min delay for APU start between cycles (in Min)
2
Starter cut-out on ground (% rpm)
46
Ignition cut-off (% rpm)
95
Max Alt for APU start in-flight (ft)
37.000
Starter cut-out-in-flight (% rpm)
60
APU max EGT during start
degrees Celsius
692 - 1.038
APU AVAIL (approx % rpm + secs)
99 + 2