APU 40C11 Flashcards
0
Q
Max Operational altitude..
A
37000ft
1
Q
Max Altitude for start…
A
30000ft.
2
Q
Max temp for start.
A
884C. (1) May be exceeded up to 925C above 25000ft during 10 seconds.
3
Q
Max temp for continuous operation…
A
680C. (5) The APU EGT may be exceeded up to 717C for 5 minutes maximum.
4
Q
Min battery temp for APU start
A
-20C
5
Q
APU will shut down at what rotor speed?
A
108%