APU Flashcards

1
Q

Can the right battery start the APU if the left is unavailable?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What must be done before starting the APU in flight?

A

Perform a fire test and cycle the master switch.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the cool down programs for the APU shutdown?

A

Dependent upon A/C altitude 20,000’. Above 20,000’ loads are shed, the APU runs at 100% for 60 seconds. Below loads are shed, RPM decreases 1/2% per second to 70% runs here for 60 seconds and shuts down.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Can the APU be started with the right engine cowl open or indicating open?

A

No on the ground, yes in flight.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Why is the APU generator switch amber?

A

It represents a non-normal situation when selected in and the APU is operating.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly