API 510 - Section - 5 Flashcards
The inspection plan shall be developed by,,,,,
inspector and/or engineer
The inspection plan shall contain the ,,,, and ,,,,,, required to monitor damage mechanisms and assure the mechanical integrity of the equipment
inspection tasks
schedule
RBI assessment, shall include a systematic evaluation of both the ,,,, and the ,,,,,, in accordance with ,,,,,
probability of failure
consequence of failure
API 580
API 581 details an RBI ,,,,,
methodology
It is essential that all RBI assessments be thoroughly ,,,, in accordance with API 580
documented
Typical examples of vessels in cyclic service include ,,,,,, and ,,,,,.
coke drums, mole sieves
pressure swing adsorbers
Susceptible Temperature Range for CUI
- for carbon and low alloy steels,,,,,,,,,
- for austenitic stainless steels,,,,,,,,,
- for duplex stainless steels,,,,,,,,,
10 °F (–12 °C) and 350 °F (175 °C)
140 °F (60 °C) and 350 °F (185 °C)
280 °F (138 °C) and 350 °F (185 °C)
With carbon and low alloy steels, CUI usually causes ,,,,
localized corrosion
With austenitic and duplex stainless steel materials, CUI usually is in the form of ,,,,,,,
external chloride stress corrosion cracking
Examples of different types of CMLs include locations for ,,,,,
- thickness measurement,
- locations for stress corrosion cracking examinations, - - locations for high-temperature hydrogen attack examinations.
when localized corrosion is expected or a concern, it is important that examinations are conducted using scanning methods such as ,,,,
Profile Radiography,
Scanning Ultrasonic techniques,
For ultrasonic scanning, Corrective procedures should be utilized when metal temperatures (typically above ,,,,,) impact the accuracy of the thickness measurements obtained
150 °F [65 °C]
A close visual inspection of pressure vessel components should not be performed until the vessel pressure is ,,,,,
at or below the MAWP.
During pressure test, applying an additional load to the valve spring by turning the compression screw is ,,,,
prohibited
Hydrostatic pressure tests of equipment having components of Type 300 series stainless steel should be conducted with ,,,or,,,having a chloride concentration of ,,,,,
potable water
steam condensate
less than 50 ppm