Annunciators Flashcards

At or below altitude set on radio altimeter

Flashing - Spoilers deployed with 13 deg or more flaps extended (normal on landing roll)

One of 10 latch pins not fully engaged or hook motor not fully retracted

- Spoilers split 6 deg or more
- Spoiler and aileron split 6 deg or more in spoileron mode

- One or both pitot heaters is INOP with switches ON
- One or both of the pitot switches is off

Fuel is below 400-500lbs in EITHER wing tank

Steady - Spoilers not lcoked down (normal if extended)

Differential pressure is 1.25psi across one or both airframe fuel filters.
FUEL IS BYPASSING FILTER

Less than 0.25psi fuel pressure to engine (light extinguishes as 1.0psi)

- Switch ON - insufficient pressure to nacelle or fan spinner or failure of valve(s) open
- Switch OFF - nacelle or fan spinner valve(s) open

- Switch is OFF
- Computer has failed with switch ON

- Steady - system is off or failed (normal during pusher)
- Flashing - In shaker range

One motor in the vertical gyro has failed

System is INOP with speed above 0.69m and autopilot disengaged.
Overspeed warning horn sounds at 0.74m

- Inverter is off
- Inverter switch is on and output is less than 90v or less than 10 volt-amps

Inverter has failed with switch on

Oil pressure on one or both engines is below 23 +/-1psi

Stabilizer structural temp is above 215 F

Windshield heat has been turned off by temperature limit.
GND - high or low limit
AIR - high limit only

Nosewheel steering is engaged

- Overtemp of pylon or duct
- BOTH lights - Manifold over pressure

Indicated generator is off or has failed

Cabin altitude has reached 8,750 ft give or take 250ft and controller has switched to manual

Wing structural temp is above 215 F

Windshield anti-ice valve is open

One or more battery temp is 140 F or more
land as soon as PRACTICAL

One or more battery temp is 160 F or more
Land as soon as POSSIBLE

The engine sync switch is on with the nose gear down and locked

Airplane is on the ground and the horizontal stabilizer is not trimmed for takeoff

Failure of either or both 275 amp limiters

Fire extringuishing bottles are armed

Fire/overheat is detected in associated engine

A red light on the master warning panel is illuminated

LOW HYD - hydraulic pressure 1,125psi or less
FUEL XFLO - Fuel xflow valve is open
L/R LO OIL - indicated engine oil pressure is low

- primary pitch is running at fast rate with flaps up
- primary pitch has a fault (potential runaway)
- wheel master (MSW) switch is pressed

Ferrous metal particles are detected in indicated engine oil

Indicated emergency battery is powering the connected systems

Indicated starter is engaged

HSI heading not within 7deg
Nacelle heat switches (or indicated switch) is on

Ignition system is activated

Indicated anti-skid generator is INOP

Indicated 275 amp current limiter has failed

- indicated pitot switch off or heat has failed

Parking brake is set or brake is not fully in after release

- illuminates momentarily when WSHLD DEFOG is set ON
- Overheat/underheat condition when ON