Aircon / Press / Ventilation Flashcards
Q1
Which valves will receive a close command when the DITCHING pushbutton is depressed (ARPO)?
- Avionics Inlet and Extract valves
- Ram air inlet
- Pack Flow Control valves
- Outflow valve (only if in AUTO mode)
- FWD cargo outlet isolation valve
[FCOM-DSC-21-20-30]
Q2
Will the DITCHING pushbutton always close the outflow valve?
Not if the outflow valve is under manual control
[FCOM-DSC-21-20-40]
Q3
Can the pilot control the outflow valve?
- Yes
- Select MAN on the MODE SEL
- Use the MAN V/S CTL switch
[FCOM-DSC-21-20-30]
Q4
How many Cabin Pressurization Controllers (CPCs) are in the pressurization system?
- 2
- Only one is used at a time and they swap roles after each landing
[FCOM DSC-21-20-30]
Q5
How do you manually switch controllers?
Switch MODE SEL to MAN for 10 seconds, then back to AUTO
[FCOM-DSC-21-20-40]
Q6
What does an amber FAULT light in the MODE SEL pushbutton indicate?
Both automatic pressure controllers are faulty
[FCOM-DSC-21-20-40]
Q7
From what source does the pressurization system normally obtain landing elevation?
FMGC database
[FCOM-DSC-21-20-40]
Q8
If the FMGC database does not supply the landing elevation, how do you set the landing elevation?
Manually by selecting landing elevation via the LDG ELEV knob.
[FCOM-DSC-21-20-40]
Q9
What protects the airframe from excessive cabin differential pressure?
2 pressure relief valves (safety valves)
[FCOM-DSC-21-20-20]
Q10
How many outflow valve motors are installed?
- 3 Total
- One for each CPC, and one for manual control
[FCOM-DSC-21-20-20]
Q11
How would a pilot manually control the pressurization?
By selecting MAN on the MODE SEL pb and utilizing the MAN v/s CTL toggle switch
[FCOM-DSC-21-20-10]
Q12
What flow rate is automatically selected when APU bleed air is in use or during single pack operation?
HI
[FCOM-DSC-21-10-50]
Q13
If the engine bleed air in-flight is too low, what will occur?
Engine speed is automatically increased to provide adequate bleed pressure
[FCOM-DSC-21-20-30]
Q14
What would cause an amber FAULT light to illuminate in the PACK 1 and/or PACK 2 pb (OOD)?
- Overheat at PACK outlet
- Overheat at Compressor outlet
- Discontinuity in switch position vs. pack flow control valve position
- NOTE: FAULT light will illuminate when no bleed air is supplied
[FCOM-DSC-21-10-50]
Q15
At what cabin differential pressure does the RAM AIR valve open?
1 PSI ∆P or less
[FCOM-DSC-21-10-20]
Q16
What causes the Pack Flow Control Valve to automatically close?
- Upstream pressure below minimum
- Pack overheat
- Engine start sequence
- Engine FIRE pb on the related side pressed
- DITCHING pb is selected
[FCOM-DSC-21-10-50]
Q17
What does an amber FAULT light in the HOT AIR pb indicate?
- Duct overheat
- The Hot Air and Trim Air valves close automatically
[FCOM-DSC-21-10-50]
Q18
How many Air Conditioning System Controllers are there & how many lanes do they have?
- 2 Air Conditioning System Controllers
- Each Air Conditioning System Controller has 2 lanes (Active/Standby)
[FCOM-DSC-21-10-10]
Q19
Describe how the Air Conditioning System Controllers regulate temperature?
- Basic temperature regulation
- Both packs produce the required outlet temperature determined by the lowest demanded zone temperature
- Optimized temperature regulation
- Hot air is added to the individual zones by the trim air valves to maintain the desired zone temperature
[FCOM-DSC-21-10-30]
Q20
What occurs when an active lane of an Air Conditioning System Controller fails?
The 2nd lane takes over
[FCOM-DSC-21-10-40]
Q21
What occurs when both lanes of an Air Conditioning System Controller (ACSC) fail?
- The related pack is lost
- The hot air pressure regulating valve and associated trim air valve(s) close
[FCOM-DSC-21-10-40]
Q22
How does the Air Conditioning System Controller configure its associated pack ram air inlet flap for takeoff and landing to avoid the ingestion of foreign matter?
- Takeoff: Pack Ram Air Inlet Flap closes when takeoff power is set and the main landing gear struts are compressed. Reopens after main landing gear strut extension
- Landing: Pack Ram Air Inlet Flap closes as soon as the main landing gear struts are compressed and speed ≥ 70 knots. Opens 20 seconds after speed < 70 knots
[FCOM-DSC-21-10-30]
Q23
If an air cycle machine (ACM) fails, what occurs?
The affected pack will operate as a heat exchanger
[FCOM-DSC-21-20-40]
Q24
What effect will the engine start sequence have on the pack flow control valves?
The pack flow control valve will close automatically
[FCOM-DSC-21-10-20]
Q25 | VENTILATION PANEL
What does the CARGO HEAT HOT AIR amber FAULT light indicate?
Duct overheat
[FCOM-DSC-21-40-30]
Q26 | VENTILATION PANEL
What is the purpose of the CABIN FANS?
To re-circulate cabin air to the mixing chamber and then back to the cabin
[FCOM-DSC-21-10-20]
Q27 | VENTILATION PANEL
With BLOWER and EXTRACT pushbuttons in AUTO how does the system operate?
- Ground – system is normally in the OPEN configuration
- Flight – system is normally in the CLOSED configuration
- Intermediate – Closed configuration except small internal flap in Extract Valve is open
[FCOM-DSC21-30-20, FCOM-DSC-21-30-60]
Q28 | VENTILATION PANEL
With both BLOWER and EXTRACT pushbuttons in OVRD (smoke configuration) what are the positions of the INLET and EXTRACT valves?
- INLET valve CLOSED
- EXTRACT valve OPEN
[FCOM-DSC-21-30-20]
Q29 | VENTILATION PANEL
What is the status of the Blower and Extract fans with the Blower and Extract valves in OVRD?
- BLOWER fan OFF
- EXTRACT fan ON
[FCOM-DSC-21-30-20]
Q30 | VENTILATION PANEL
When is air conditioning introduced into the avionics compartment?
- Abnormal operation
- SMOKE configuration
[FCOM-DSC-21-30-20]
Q31 | VENTILATION PANEL
Is the skin heat exchanger ever bypassed in flight?
Yes; during SMOKE configuration
[FCOM-DSC-21-30-20]
Q32 | VENTILATION PANEL
What does an amber FAULT light on the BLOWER pushbutton indicate?
- SMOKE warning is activated
- Computer power supply failure
- Low blower pressure
- Duct overheat
[FCOM-DSC-21-30-60]
Q33 | VENTILATION PANEL
What does an amber FAULT light on the EXTRACT pushbutton indicate?
- SMOKE Warning is activated
- Computer power supply failure
- Low Extract pressure
[FCOM-DSC-21-30-60]
Q34 | VENTILATION PANEL
With 2 FAULT lights on the VENTILATION panel, are there any other indications?
- Yes
- The SMOKE light in the GEN 1 LINE pushbutton
[FCOM-DSC-26-30-20]