The Cabin Temperature controller on the flight deck sets a Master temperature. When selected to the 12 o’clock position, what temperature is commanded?
A. 65 - 85°
B. 75°
C. 65 - 75°
D. 70°
75°
The recirculation fans draw air from the cabin, through filters, then reintroduce it into the cabin distribution ducts. Turning OFF a fan will result in increased cabin air flow.
A. True. B. False.
FALSE
Recirculation fans MUST remain ON when using ground conditioned air for cooling.
A. True. B. False.
FALSE
What does the “PACK L” EICAS message mean?
A. The left pack is inoperative.
B. A pack component has failed and the pack has reverted to standby cooling. C. A bleed leak has been detected and the pack has shut down.
D. The associated pack is operating at maximum capacity
The left pack is inoperative.
What are the uses of engine bleed air?
A. TAT probe aspiration.
B. Ice detection probe anti-ice.
C. Engine Nacelle and Core anti-ice.
D. Both B and C.
Engine Nacelle and Core anti-ice.
The forward cargo compartment is heated by ?
A. Forward equipment ventilation system discharge air.
B. Thermal blankets.
C. Inline electric heater in the cargo compartment.
D. A and C are correct.
A and C are correct.
A loss of forward equipment cooling on the ground results in .
A. A steady horn sounding in the nose wheel well.
B. EQUIP COOLING FWD EICAS message.
C. Equipment cooling does not operate on the ground.
D. Both A and B are correct.
Both A and B are correct.
The pressurization system normally receives flight parameters .
A. From the Sabre pressurization uplink.
B. From ambient pressure and the FMC flight plan data.
C. From the Landing Altitude settings on the overhead pressurization panel.
D. Pressurization entries on the AIR synoptic.
From ambient pressure and the FMC flight plan data.
Pressing the AIR COND RESET switch on the overhead panel (per non-normal) will:
A. Reset a failed recirculation fan.
B. Reset a failed trim air valve.
C. Reset a pack fault
D. All the above.
All the above.
An EICAS message of PACK MODE (L or R) indicates _______.
A. The pack is operating in the Standby Cooling mode.
B. The pack may shut down at lower altitudes and higher outside air temperatures when ambient conditions do not permit standby cooling.
C. The pack has failed and a descent to an altitude below FL250 is required.
D. A and B are correct.
A and B are correct.
With either outflow valve failed fully open, a loss of pressurization WILL occur.
A. True.
B. False.
TRUE
With a PACK L or PACK R message displayed on EICAS due to an overheat:
A. The pack reverts to standby cooling.
B. The pack flow rate is reduced to the minimum to keep the pack outlet temperature at an acceptable level.
C. The pack automatically shuts down.
D. The pack automatically switches to the controller for the opposite pack if available.
The pack automatically shuts down.
13) If the cabin temperature controller fails, the pack(s) will:
A. Modulate to keep cabin temperature between 40 and 110 F.
B. Maintain cabin temperature within 15 degrees of TAT.
C. Trip and automatically shut down.
D. Maintain the last cabin temperature or 75 F.
Maintain the last cabin temperature or 75 F.
Forward equipment cooling system provides ventilation to the FWD E/E bay and electronic equipment on the flight deck.
A. True.
B. False.
TRUE
15.) The pressurization system ____ uses to provide Landing altitude barometric pressure correction.
A. The First Officer’s radio altimeter reading
B. The stored FMC TDZE
C. The standby altimeter setting
D. The Captains altimeter setting
The Captains altimeter setting