What is the flight deck temperature range with the Flight Deck (FLT) temperature selector in AUTO?
65F to 85F (18C to 29C)
What valve are you controlling when you select MAN with the flight deck temperature controller?
Flight deck trim air valve
What does the Zone System (SYS) Fault Light indicate?
- Temperature zone duct overheat
- Zone temperature controller fault has occurred
- Master Trim air valve failed closed
- Trim air switch off
- Master trim air valve closed and pack air continues to flow
What is the temperature range with the main deck and forward and aft lobe temp selectors in AUTO?
40F - 85F (4C - 29C)
Under what conditions would trim air be unavailable to the flight deck, upper deck, crew rest, and main deck?
- EICAS advisory “TEMP ZONE” displayed
- Center section of the bleed duct is isolated
- EICAS advisory message “TRIM AIR OFF” is displayed
- The Master Trim Air switch is “OFF”
If trim air is not available to the flight deck, upper deck, crew rest, and main deck distribution system, how is temperature controlled in the cabin?
- Backup modes control temperature
- If the flight deck temp selector setting is available to the PTC, pack outlet temperature of all packs is regulated to an average temp between 65F and 85F as set by the Flt Deck Temp selector
- If unavailable to the PTC- the last temp set
- If last temp unavailable to the PTC, then to 75F (24C)
What target temperature is set to the upper deck and crew rest zone when electrical power is initially applied to the aircraft?
75F (24C)
How many pack temperature controllers (PTC) are provided?
Two - A & B
How many separate channels are provided in the PTCs?
Each PTC has 3 separate channels- one for each pack
What happens if a pack temperature controller (PTC) detects a fault in a pack channel?
Control of the respective pack switches to the other PTC
How can you restore pack operation for a failed PTC?
Push the Pack Reset Switch
What would happen if a fault or an overheat of the PTC is deteced?
The respective pack valve closes, resulting in a pack shutdown.
What are the 7 temperature zones for the 400F?
- Flight deck
- Upper deck
- Crew Rest
- FWD Main Deck
- AFT Main Deck
- FWD Lower Lobe
- AFT Lower Lobe
What is the function of the Lower Lobe Cargo Conditioning AIR FLOW RATE selector? (LLCCAFR)
Provides FWD and AFT lobe cargo air conditioning.
With the LLCCAFR switch “OFF”, what controls pack outlet temperature?
The flight deck, upper deck, and crew rest zone requiring the coolest temp