AIR CONDITION Panel Flashcards

1
Q

What computers monitor and control the pneumatic system?

A

o 2 Bleed Monitoring Computers (BMC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If one BMC fails, can the other take over?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The PACK FLOW selector has LO, NORM, and HI position’s. What is the rule of thumb
for setting?

A

o If the total cabin occupancy (flight attendant + passengers) is 114 people or less,
place the PACK FLOW selector to the LO position.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What would cause an amber PACK FAULT light to illuminate?

A

o Pack Overheat (OR)

o Switch position disagreement with pack FCV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does the amber FAULT light in the APU BLEED pb indicate?

A

o Bleed leak

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What causes the amber FAULT light on the ENG BLEED PB?

A

o Engine bleed temperature or pressure limit exceeded.
o Switch / Valve Position disagreement.
o Bleed Leak detected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens when the Ram Air pb is pressed?

A

o This pb is used to open the emergency ram air inlet. In the normal position
(lights out), the emergency ram air inlet is closed. When the guard is lifted, and
the pb depressed, “ON” illuminates blue, and the ram air inlet opens. “RAM AIR
ON” is displayed in green on the memo display. Once the cabin differential
pressure is less than 1 psi, the outflow valve will automatically open (if the
cabin MODE SEL pb is in AUTO). The emergency ram air inlet and the outflow
valve will not open if ditching has been selected.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What logic controls the X-Bleed valve when the X-BLEED switch is in AUTO?

A

o When APU bleed valve is OPEN, the X-Bleed valve is OPEN.

o When APU bleed valve is CLOSED, the X-Bleed valve is closed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the function of the HOT AIR pb?

A

o The hot air valve controls the supply of hot air to all of the trim air
valves which maintain the selected temperature in each zone.
o Valve position is controlled by the HOT AIR pb. The valve
automatically closes in the event of a fault.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What does the amber HOT AIR FAULT light indicate?

A

o Duct overheat. The Hot Air valve close automatically.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How does the system optimize the temperature in each of the three zones?

A

o Trim Air Valves
o To maintain the selected zone temperature, the trim air valves under control of the
zone regulator, add hot air, if necessary, to the air flowing from the mixing unit.
o This allows for air temperatures to be controlled independently in each zone.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What effect will the engine start sequence have on the pack flow control valves?

A

o The pack flow control valve will close automatically.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

After engine start with the APU BLEED pb ON, what source is supplying bleed air to the packs?

A

o APU Bleed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly