AIR Flashcards

1
Q

If the APU bleed is left on during climb, when will it automatically close?

A

closes at 25,000ft and reopens at 23,000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many pack controllers? what if they fail?

A

1 controller per pack. If it fails, the pack outlet temp will be regulated between 48 and 59 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What happens if a Zone controller fails? How many channels?

A

Two channels. If the zone controller fails, the temp will be regulated to 68 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When should you select the Pack flow to Low? (80%)
What are the other settings?

A

When less than 60% of economy is occupied. Less than 200 Pax total all zones.
Norm 100% or auto (mcdu input)
High - 120% - for hot and humid conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the pack flow on the ground with APU on?

A

125%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How is the FWD cargo temp controlled?

A

Heated from the left (hot 1) cooled from the right (pack 2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How is the cockpit heated?

A

Hot air 1, via a restricter valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Ram air on the left lower side of the fuselage. Purposes?

A

Used in case of dual pack failure.
Used for Smoke Fire Fumes QRH procedure.
Will not open if Delta P is greater than 1.
Ram air Pb does not work if ditching Pb is selected. (OCRAP)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly