A350 Flashcards

1
Q

Where can the EVAC alarm be initiated from in the cabin?

  • FAPs and AAPs
  • All crew stations
  • Right-hand crew seats
  • FAPs only
A

• FAPs and AAPs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Who can authorise the activation of the AUTO FLUSH?

  • Galley Leeds
  • SCCM
  • Flight crew
  • Any crew member
A

• Flight crew

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the indications in the cabin if the cabin altitude exceeds approximately 14,000ft?

  • Masks drop and automatic PRA plays
  • Red flashing light on all ACPs, cabin pressure warning text on all AIPs
  • Cabin pressure page illuminate on FAPs
  • Triple low chime every 30 seconds, exit signs illuminate
A

• Masks drop and automatic PRA plays

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

During normal operation, what action must be taken if the white slide armed light illuminates?

  • Continue to open the door and advise an engineer
  • Immediately let go of the door and block the exit
  • Lower the control handle, disarm the door, inform the Commander
  • Commence an emergency evacuation
A

• Lower the control handle, disarm the door, inform the Commander

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the process for operating a HAFEX?

  • Lift the catch and pull the firing pin
  • Remove the pin, squeeze the lower lever level with a side of the bottle
  • Remove the pin, squeeze the top lever downwards
  • Lift the catch and squeeze the two levers together
A

• Remove the pin, squeeze the top lever downwards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How is the doorway reduced at D1, to ensure only one person can evacuate at a time?

  • Attach the restrictor line before opening the door
  • Only half the door opens in emergency mode
  • Single lane slide raft fitted with IFAR
  • Cabin crew member must partially block the exit
A

• Single lane slide raft fitted with IFAR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If the smoke detector has been activated what will the indication be on the ACP?

  • Steady blue
  • Flashing amber
  • Steady green
  • Flashing red
A

• Flashing amber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When not occupied how should the harness of the crew seat be stowed?

  • Unfastened
  • Dangling down the side of the seat
  • Fastened
  • Lap strap in the recess recess
A

• Fastened

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where is the switch to turn off the toilet water heater?

  • Waste page of the FAP, select the relevant toilet
  • Next to the water shut off valve, underneath the sink
  • Toggle switch on the base of the heater
  • Rocker switch on the side of the black box
A

• Toggle switch on the base of the heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What systems will be lost if the ‘PAX SYS’ is turned off at an FAP?

  • Cabin lighting and all galley power
  • PED power and passenger call bells
  • IFE, passenger call bells and galley power
  • Seat power, PED power, IFE and Wi-Fi for all cabins
A

• Seat power, PED power, IFE and Wi-Fi for all cabins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the pre-flight check on the air liquide PBE?

  • Temper seal intact and red indicator visible
  • Box not bulging and indicators touching
  • Seal intact and release handle stowed
  • Indicator is green and seal is intact
A

• Indicator is green and seal is intact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For LAVs 83 and 84 (located by D4L and D4R) where is the door stopper at located, to keep the door open?

  • On the doorframe at shoulder height
  • On top of the door
  • Under the ceiling rail
  • Lavatory page on the FAP
A

• On top of the door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What will happen to the flight deck door in the event of a rapid decompression in the cabin?

  • Nothing, there is a gap all the way around which will allow the pressure to equalise
  • The door remains shut and the evacuation panel opens
  • The top half of the door will open and attach to the locking bolt
  • The door will open into the cabin and secure against the locking clasp
A

• The door remains shut and the evacuation panel opens

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How many portable oxygen bottles are located in the CCRC?

  • 1
  • 6
  • 3
  • None
A

• 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the code to access the CRCs (Crew Rest Compartments)?

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where are the MRTs located in the cabin?

  • In galley stowages
  • Underneath crew seats
  • In overhead lockers
  • Adjacent to PSUs
A

• Underneath crew seats

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What would a continuous high chime in the CRCs (Crew Rest Compartments) indicate?

  • Evacuation alarm
  • Decompression
  • Smoke detector activated
  • Emergency call
A

• Decompression

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Which part of the Club World Suite can items be retrieved from?

  • Down the back of the seat, on the netting
  • Down the side, on the runner
  • Anywhere
  • Underneath the seat pan
A

• Down the back of the seat, on the netting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Where can the emergency lights be activated from in the cabin?

  • Lighting page of the FAP at D4L
  • FAP subpanel D1L and D4L
  • FAP D1L and D4L and the AAP
  • Miscellaneous page of the AAP D2L and D3L
A

• FAP subpanel D1L and D4L

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Where are the osmosis pump and parachute flare located?

  • Survival pack, stowed on the aircraft
  • Dog box storage is near dual lane slide rafts
  • Survival kit, connected to the slide raft
  • And overhead locker at D4L
A

• Survival pack, stowed on the aircraft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Which crew member sits at D1L outboard?

  • No.12
  • No.9
  • No.11
  • No.10
A

• No.10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Where is the cabin secure button activated from?

  • All FAPs and AAPs
  • FAP at D1L
  • On the handset at D1L and D4L
  • Bulkhead by LAV 11
A

• FAP at D1L

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is the minimum required number of cabin crew, returning to base?

  • 7
  • 6
  • 9
  • 8
A

• 8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What is the purpose of the pause when opening the door?

  • To ensure the slide armed light does not illuminate
  • To ensure the cabin is not pressurised
  • To make sure the door reverts to manual
  • To give groundstaff time to move out of the way
A

• To ensure the slide armed light does not illuminate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

What is the preflight check for the HAFEX?

  • Indicator is green and pin is in place with the seal intact
  • In date and gauge shows full
  • Pin and read disc are in place
  • Seal is intact and catch is down
A

• Indicator is green and pin is in place with the seal intact

26
Q

Where is the ‘H’ lever located, to move the pilot seat rearward?

  • Under the forward edge
  • Above the inertia lock
  • Inboard
  • Outboard
A

• Inboard

27
Q

How is the 45 minutes of oxygen, in the PSUs produced?

  • Chemical generator
  • Individual portable units
  • Gaseous ring main
  • Gaseous cylinder
A

• Gaseous cylinder

28
Q

How do flight crew advise the cabin crew that the FCRC is occupied?

  • Place and occupied sign outside the FCRC door
  • Contact the SCCM and advise them to turn on the light in the galley
  • Press compartment occupied button to eliminate light in the forward galley
  • FCRC occupied illuminates on DBPs and AIPs
A

• Press compartment occupied button to eliminate light in the forward galley

29
Q

What does an amber rectangle on the doors page of the FAP indicate?

  • Door is closed and slide disarmed
  • Door is open
  • A slide has been blown inadvertently
  • Door is closed and slide is armed
A

• Door is closed and slide disarmed

30
Q

Which crew member is responsible for checking the AVIA pulse bottles?

  • No.4
  • No.5
  • No.2
  • No.8
A

• No.2

31
Q

How is the EVAC alarm activated from an AAP?

  • Does Page - select CMD
  • Press CMD on the front screen
  • Press EVAC CMD and then press OK
  • Lift the Perspex cover and press EVAC
A

• Press EVAC CMD and then press OK

32
Q

Pressing SMOKE RESET on an AAP will reset which smoke detector indications?

  • The indication on ECAM and local chimes
  • Aural and visual (ACP and AIP) alerts in the entire cabin
  • The chimes in the entire cabin and the light on the toilet wall
  • Aural and visual (ACP and AIP) alerts in the local area
A

• Aural and visual (ACP and AIP) alerts in the local area

33
Q

How is a trolley removed/re-stowed next to D4R?

  • Slowly to be able to ease it past the slide container
  • The same as any other trolley storage
  • It is not possible to remove it once the door is closed
  • Release the sliding cart guide to make it possible to angle the trolley
A

• Release the sliding cart guide to make it possible to angle the trolley

34
Q

How is power isolated to a block of seats?

  • Operate the toggle switch at the base of the inboard seat
  • Contact the flightcrew and ask them to pull the relevant circuit breaker
  • Via the “IFE power” page on an FAP
  • Using micro switch is on the RCC at D1L1L
A

• Via the “IFE power” page on an FAP

35
Q

What is the procedure for opening a door in the event of a ditching?

  • Power assist will fail, enlist the help of an ABP
  • Pull the manual inflation handle as soon as the doors open
  • Do not use forward and rear doors, redirect pax to doors 2 and 3
  • DISARM the door before opening
A

• Pull the manual inflation handle as soon as the doors open

36
Q

Where are the majority of portable oxygen bottles stowed?

  • In dog boxes at the end of each cabin
  • Underneath crew seats
  • Above crew seats
  • In overhead lockers
A

• In overhead lockers

37
Q

What will happen to the flight deck door in the event of a rapid decompression in the flight deck?

  • The decompression panels will release and fall into the cabin
  • The top half of the door will open and attach to the locking bolt
  • It will automatically open
  • Nothing, there is a gap all the way around which will allow the pressure to equalise
A

• It will automatically open

38
Q

Which crew member sits at D4R inboard?

  • No.11
  • No.12
  • No.9
  • No.10
A

• No.12

39
Q

Where are HAFEX located in the cabin?

  • In dog boxes at the back of each zone
  • In overhead lockers
  • In the headrest of the crew seats
  • Underneath crew seats
A

• Underneath crew seats

40
Q

What escape devices are fitted at doors 2, 3 and 4?

  • Dual lane slide rafts
  • Single lane slide rafts
  • Dual lane slides
  • Single lane slides
A

• Dual lane slide rafts

41
Q

Charging the photoluminescent strip takes 15 minutes, what is the procedure?

  • Ensure lockers are closed, avoid covering the strips and select cabin lighting to BRT
  • Open the lighting page on the FAP and select charge photoluminescent strips
  • Power is supplied by the aircraft batteries so there is no requirement to charge the strips
  • Open all the lockers and select cabin lighting to DIM 2
A

• Ensure lockers are closed, avoid covering the strips and select cabin lighting to BRT

42
Q

Which doors are fitted with single lane slide rafts?

  • Doors 2 and 3
  • Doors 1
  • All doors
  • Doors 4
A

• Doors 1

43
Q

How is an emergency call made to flight crew, cabin crew and crew in the CRC (crew rest compartment)?

  • Press and hold PTT
  • Press 2 2 2 then SEND
  • Press and hold EMER for at least 1 sec
  • Press PRIO CONF then SEND
A

• Press and hold EMER for at least 1 sec

44
Q

In order to increase visibility, where have FRESNEL LENS been fitted?

  • Flight deck door
  • Cabin doors, lower half of the window
  • Passengers windows
  • Flight deck windows
A

• Cabin doors, lower half of the window

45
Q

What are the indications in the CCRC that the smoke detector has been activated?

  • PRA automatically plays, lighting 100%
  • Aural alerts, affected area highlighted in red on AIP, lighting 100%
  • Aural alert (continuous high chime), PSU deploys
  • EMER call from the flight crew or the SCCM
A

• Aural alerts, affected area highlighted in red on AIP, lighting 100%

46
Q

Which crew member sits at D2R forward facing?

  • No.10
  • No.9
  • No.12
  • No.6
A

• No.9

47
Q

What is the procedure to disconnect a slide raft?

  • Use the knife to cut/unpick the daisy chain attachment line
  • Select disconnect on the DOORS PAGE on the FAP
  • Lift the girt flap, pull the girt release handle, pull the mooring line release handle
  • Open the ditching pouch, pull the release handle
A

• Lift the girt flap, pull the girt release handle, pull the mooring line release handle

48
Q

What indicates that a passenger has pulled the emergency handle on the Club World Suite?

  • Door unlocked illuminates on touchscreen
  • Red pin is visible
  • Blue light illuminates on door frame
  • CAUT light on FAP
A

• Red pin is visible

49
Q

During normal operation, what action must be taken if the red cabin pressure light illuminates?

  • Partially raise the handle to see if the alarm sounds
  • Continue to open the door and then inform an engineer
  • Initiate an evacuation
  • Do not open the door, inform the commander
A

• Do not open the door, inform the commander

50
Q

What is the correct action if the toilet flush button is flashing amber?

  • Initiate the firefighting drill
  • Access the waste page on the FAP and select reset
  • Flush the toilet - the waste bowl is full
  • Do not press - maintenance is in progress
A

• Do not press - maintenance is in progress

51
Q

Where is the gust lock located?

  • Under the Perspex cover
  • In the l door frame
  • In the assist handle attached to the door
  • On top of the door assembly unit
A

• In the assist handle attached to the door

52
Q

Where would you find the cabin secure button?

• Bulkhead by LAV 11
• All FAPs and AAPs
• FAP at D1L
• On the handset at D1L

A

• FAP at D1L

53
Q

What is the emergency code to gain access to the flight deck?

A

54
Q

How do you disconnect a slide raft?

• Select disconnect on the DOORS PAGE page on the FAP
• Use the knife to cut/unpick the daisychain attachment line
• Lift the girt flap, pull the girt release, handle, pull the mooring line release handle
• Open the ditching pouch, pull the release handle

A

• Lift the girt flap, pull the girt release, handle, pull the mooring line release handle

55
Q

In the event of a smoke/fire from an oven in the rear galley, that persists after you have turned it off, what would you do?

• Press smoke reset a hard key under the FAP
• Pull the oven out of it stowage
• Select smoke page on FAP and isolate that oven
• Switch off the main gallery power switch

A

• Switch off the main gallery power switch

56
Q

In a decompression, the aircraft automatically descends. How do you know the flight crew are flying the plane?

• The SCCM will make a conference call
• Triple hi hi lo chime
• Flight crew will make a PA
• Continuous hi chime

A

• Flight crew will make a PA

57
Q

When the door is armed, where is the pin stowed?

• Thrown into an SEP cupboard
• Under the crew seat next, to the corresponding door
• In your pocket
• In the designated galley storage

A

• Under the crew seat next, to the corresponding door

58
Q

How would you use a HAFEX?

• Remove the pin, squeeze the lower lever level with the side of the bottle
• Lift the catch and squeeze the two leavers together
• Lift the catch and full the firing pin
• Remove the pin, squeeze the top lever downwards

A

• Remove the pin, squeeze the top lever downwards

59
Q

How would you make an Emergency call to the Flight Crew, Cabin Crew and crew in a CRC (Crew Rest Compartment)?

• Press and hold the EMER for at least 1 sec
• Press ‘PRIO’, ‘CONF’ then SEND
• Press and hold PTT
• Press ‘2’, ‘2’, ‘2’ then SEND

A

• Press and hold the EMER for at least 1 sec

60
Q

During normal operation, what would you do if the red cabin pressure light illuminates?

• Do not open the door, inform the commander
• Partly raise the handle to see if the alarm sounds
• Initiate an evacuation
• Continue to open the door and then inform an engineer

A

• Do not open the door, inform the commander

61
Q

In the event of a smoke, fire or fume event, how would you turn off the secondary RCC at 4R?

• Toggle switch in the club kitchen
• IFE panel at 1R
• Via the FAP - PAX SYS or IFE page
• Circuit breaker panel in the rear galley

A

• Via the FAP - PAX SYS or IFE page

62
Q

When must the folding table at D1R be stowed?

• All stages of the flight
• During TTOL (Taxi, Take-off/Landing)
• During cruise
• Boarding and disembarking

A

• During TTOL (Taxi, Take-off/Landing)