Q
When does the RAT automatically extend?
A
Loss of power to both AC busses 1 and 2.
2
Q
With the RAT extended, prior to emergency generator coupling (approximately 8 seconds), what busses are powered?
A
Bat 1 powers AC ESS bus through the static inverter. Bat 2 powers the DC ESS bus.
3
Q
With the RAT extended and the emergency generator couples, what busses are powered?
A
AC ESS, AC ESS SHED, DC ESS, and DC ESS SHED