A/C testing and service - part A 403cA Flashcards

1
Q

When you are using any refrigerant or working on an air conditioning system, you must always wear at least one of these:
(3)

A
  • safety goggles.
  • safety glasses with side shields.
  • a face shield.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When exposed to an open flame, refrigerants that contain fluorocarbons break down and produce:

A

dangerous poisonous vapours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The maximum allowable filling limit for any refrigerant container is:

A

80% of its internal volume.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

It is acceptable to recover different types of refrigerants into the same container, producing a refrigerant cocktail, as long as you reuse it afterwards.
T/F

A

false

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The manifold gauge set’s ________________________________ registers the
pressure, in the range of 0 to 500 psi, which is present in the right hand (red) hose.

A

high-pressure (red) gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The manifold gauge set’s _________________________________ registers the
pressure in the range of 0 to 150 psi, which is present in the left hand (blue) hose.

A

low-pressure compound (blue) gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The manifold gauge set’s centre mounted utility (yellow) hose can be used to:
(5)

A
  • recover refrigerant from the air conditioning system
  • pressure test (leak check) the air conditioning system with nitrogen
  • evacuate air and moisture from the air conditioning system
  • add oil to the air conditioning compressor with the use of an oil injector
  • recharge the air conditioning system with refrigerant
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The purpose of using a high capacity vacuum pump when servicing an air conditioning system is to remove the moisture and air that is hidden in the hoses and components of a closed air conditioning system.
T/F

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A micron gauge can be used to accurately measure _______________
that has been reached in the air conditioning system as it is being evacuated.

A

the level of vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If the bubble crimp produced on a bead lock fitting is properly centred and looks
regular, you can check its accuracy with the use of a _______________.

A

micrometer.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The bent fins of the air conditioning condenser and evaporator can be straightened
by the use of a ______________.

A

fin comb.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A damaged or loose ________________________ can cause a

refrigerant leak large enough to render an air conditioning system useless in a matter of hours.

A

Schrader valve core

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Quality troubleshooting and service procedures always start with a ______________
____________________ of the HVAC system.

A

visual inspection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The first step in diagnosing the source of an HVAC system cooling problem is to
________________________________.

A

gather information.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If the HVAC visual inspection has eliminated the cab heating system from being the cause of the cooling malfunction, but has not helped to isolate the air conditioning
problem, you should conduct an air conditioning system ____________________
______________________.

A

performance test.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Properly operating air conditioning system temperatures and pressures vary with
__________________________, __________________________and
________________________________.

A

ambient temperatures, humidity levels and condenser size.

17
Q

If a blockage to refrigerant flow (internal restriction) occurs inside the air
conditioning system, ___________________ system pressures will result.

A

low

18
Q

A malfunctioning air conditioning _____________________________ will cause you to observe higher than normal low side pressure readings, lower than normal high side pressure readings and high temperature readings in HVAC duct airflows.

A

compressor

19
Q

________________ pressure readings can be caused by two or more refrigerants mixed inside the air conditioning system.

A

High

20
Q

Dirt and debris lodged in the condenser fins will cause ________________________ operating air conditioning system pressure readings.

A

higher than normal