900 APU Flashcards

1
Q

The APU compartment is made of

A

Titanium

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When are the RPM and EGT gauges shown on the EICAS status page

A

Upon selection of the APU PWR/FUEL switchlight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

APU Max operating altitude (900)

A

41,000’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Max altitude for starting APU (900)

A

37,000’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Max altitude for bleed air (900)

A

25,000’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Fuel for the APU comes from

A

The left collector tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where is the inlet door located

A

Upper left side of the rear fuselage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does the air inlet door ram air provide air for

A

APU operation

And

Oil cooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What happens when the power fuel switch light is pressed

A

APU IN BITE STATUS MSG

APU SOV STATUS MSG

RPM/EGT gauges

Door opens

APU fuel pump turns on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens when the start stop switch light is pressed

A

Starter is energized(
APU START MSG)

Ignition
Fuel introduced

Start legend on the APU panel comes on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When the start stop switch light is selected to stop the APU

A

The APU will automatically shed it’s loading and shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When the power fuel switch light is deselected

A

The fuel shut off valve closes

Power is removed from the ECU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Minimum ambient temperature for starting?

A

-40c

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How many starts in one hour?

A

Three starts or start attempts in any hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the primary purpose of the APU?

A

Electrical power and air for engine starts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The APU door is controlled by the?

A

ECU

17
Q

What is the APU and main battery voltage required before we start the APU?

A

22V

18
Q

How does the APU start sequence differ in the air from on the ground?

A

In-flight…The APU door will not open until the start stop button is selected

19
Q

Apu door will automatically close when?

A

During shutdown or FIRE

20
Q

When does the AVAIL light turn on

A

99% RPM +2 seconds